Fujitsu AOT12LSAC Operating Manual Download Page 10

10

SLEEP TIMER OPERATION

Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped.

To Use the SLEEP timer

While the air conditioner is operating or stopped, press the
SLEEP button (Fig. 6 

L

).

The SLEEP TIMER mark ( 

 ) on the Remote Control Unit’s Display will light.

Within 3 seconds after ( 

 ) light the time can be changed by pressing SLEEP

button once again.
Each time the button is presssd, the time changes in the following order:

About three seconds later, the entire display will reappear.
The Indoor Unit’s OPERATION Indicator Lamp (red) (Fig. 3 

5

) and the TIMER indica-

tor lamp (green) (Fig. 3 

6

) light.

To Change the Timer Settings

Press the SLEEP button once to display the last setting time.
Press the SLEEP button again to change the time.

Each time the button is pressed, the time changes in the following order (Change
from the last setting time):

To Cancel the Timer:

Press the CANCEL TIMER button.

To Stop the Air Conditioner During
Timer Operation:

Press the START/STOP button.

About the SLEEP timer

To prevent excessive warming or cooling during sleep, the SLEEP timer function automatically modifies the thermostat set-
ting in accordance with the time setting. When the time has elapsed, the air conditioner completely stops.

During Cooling/Dry operation:

When the SLEEP timer is set, the thermostat setting is auto-
matically raised 1 °C every sixty minutes. When the ther-
mostat has been raised a total of 2 °C, the thermostat set-
ting at that time is maintained until the set time has elapsed,
at which time the air conditioner automatically turns off.

SLEEP timer setting

2°C

3°C

4°C

30
minutes

1°C

1 hour

1 hour
30 minutes

Set time

Set time

1 hour

1 °C

2 °C

During Heating operation:

When the SLEEP timer is set, the thermostat setting is
automatically lowered 1°C every thirty minutes. When the ther-
mostat has been lowered a total of 4°C, the thermostat setting
at that time is maintained until the set time has elapsed, at which
time the air conditioner automatically turns off.

SLEEP timer setting

Confirmation of TIMER's time

To confirm each TIMER's time, press SET button while setting OFF TIMER, ON TIMER or SLEEP TIMER (or during running).
If SET button is pressed, it will be changed into time display from temperature setting display. The left time of the TIMER
which is being set currently will be displayed for 5 seconds, then it will return to temperature setting display.

→   

1.0

   2.0

   3.0

   5.0

   7.0

    9.0(hour)

(RESET)

→   

1.0

   →   

2.0

  →   

3.0

   →  

 5.0

    →   

7.0

    →    

9.0(hour)

(RESET)

9312556052-En.pm6.5

2003.5.14, 9:17 AM

10

Summary of Contents for AOT12LSAC

Page 1: ...L P N9312556052 01 Indoor Unit AST9LSACW AST12LSACW Outdoor Unit AOT9LSAC AOT12LSAC HEAT COOL MODEL REVERSE CYCLE ROOM AIR CONDITIONER WALL MOUNTED TYPE On account of measuring the distance from margin to content Cover and P16 are printed as A4 size The others are printed as B5 Scale 86 5 ...

Page 2: ...ct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for ext...

Page 3: ...aised during the period of operation When the set time is reached the unit automati cally turns off WIRELESS REMOTE CONTROL UNIT The Wireless Remote Control Unit allows convenient con trol of air conditioner operation SWING OPERATION The Air Flow Direction Louvers swings automatically up and down so that the air speeds to every nook and corner of your room REMOVABLE OPEN PANEL The indoor unit s Op...

Page 4: ...RATION TIMER SUPER QUIET COIL DRY 9 Fig 5 Fig 1 Fig 2 Fig 3 Fig 4 Fig 7 This figure shows the control display when all indicator lamps are on It may differ from the actual display Fig 6 NAME OF PARTS 9312556052 En pm6 5 2003 5 14 9 17 AM 4 ...

Page 5: ...R button T CANCEL TIMER button U FAN CONTROL button V START STOP button W AIR FLOW DIRECTION button X SWING button Y ACL button Z TEST RUN button This button is used when installing the conditioner and should not be used un der normal conditions as it will cause the air conditioner s thermostat function to op erate incorrectly If this button is pressed during normal op eration the unit will switch...

Page 6: ...perating range becomes ap preciably reduced replace the batteries and press the ACL button with the tip of a ballpoint pen or other small object Turn on the Power 1 Connect the Power Supply Plug Fig 1 E to an electri cal outlet in the case of a direct line connection turn on the circuit breaker Load Batteries R03 LR03 2 1 Press and slide the battery compartment lid on the re verse side to open it ...

Page 7: ...Press the FAN CONTROL button Fig 6 U Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As ...

Page 8: ... speed for about 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Au...

Page 9: ...IMER mark on the Remote Control Unit s Display is flashing The flashing will continue for about 30 seconds 3 Press SET button Fig 6 S to select ON TIMER opera tion The ON Timer mark will be shown on the Remote Control Unit s Display The Indoor Unit Timer Indicator Lamp green Will light It can not be used during OFF TIMER operation To Cancel the Timer Press the CANCEL TIMER button To Change the Tim...

Page 10: ...et ting in accordance with the time setting When the time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every sixty minutes When the ther mostat has been raised a total of 2 C the thermostat set ting at that time is maintained until the set time has elapsed at which time the air conditio...

Page 11: ...at ing range for more than 30 minutes they will automatically return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the AIR FLOW DIRECTION button Fig 6 W Each time the button is pressed the air direction range will change as follows 1...

Page 12: ... The COIL DRY Display Fig 7 c will light Then it will disappear after 20 minutes To cancel COIL DRY Operation Press the START STOP button during COIL DRY Operation The COIL DRY Display Fig 7 c will go out Then the operation stops About COIL DRY Operation Press the COIL DRY button again during COIL DRY Operation COIL DRY Opera tion can be reset The COIL DRY Operation cannot get rid of the existed m...

Page 13: ...ry with a clean soft cloth 3 Replace the Open Panel 1 Insert the mounting shafts of the Open Panel into the hole of the hinge and install it 2 Install the Open Panel at the other side in the same procedure with 1 3 Press the place where the arrow on the diagram indi cates and close the Open Panel CLEANING AND CARE CAUTION Before cleaning the air conditioner be sure to turn it off and disconnect th...

Page 14: ...densation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor uni...

Page 15: ...roduced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating mode under conditions o...

Page 16: ... to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high hu...

Reviews: