background image

To stop test running, press the START/STOP button.
For the operation method, refer to the operating manual and
perform operation check.
Check that there are no abnormal sounds or vibration
sounds during test running.

When EE : EE blinks at the current time display, there is an
error inside the air conditioner.  If the SET TIME button ( )
and TEMP./DAY button ( ) are pressed simultaneously for
more than three seconds, the self diagnosis check will start
and the error contents will be displayed at the current time
display.  When the operation lamp lights, press the
START/STOP button and after operation lamp goes off,
perform the same operation.  Process the error contents by
referring to (Table 1).

NON STOP

CLOCK

TEMP

AUTO

TIMER

MODE

SET

START/STOP

CLOCK ADJUST

SET TIME

TEMP./DAY

FAN

CONTROL

MASTER

CONTROL

2

1

HIGH

COOL

DEFROST

DAY OFF

AUTO

TIMER

MODE

SET

START/STOP

CLOCK ADJUST

SET TIME

TEMP./DAY

FAN

CONTROL

MASTER

CONTROL

2

1

DAY OFF

ENERGY SAVE

ENERGY SAVE

ZONE

Stop operation.

Table 1

Error cord

Error contents

Communication error
(indoor unit         remote controller)

Communication error
(indoor unit         outdoor unit)

Room temperature sensor open

Room temperature sensor shortcircuited

Indoor heat exchanger temperature sensor open

Indoor heat exchanger temperature sensor 
shortcircuited

Outdoor heat exchanger temperature sensor 
open

Outdoor heat exchanger temperature sensor 
shortcircuited

Power source connection error

Float switch operated

Outdoor temperature sensor open

Outdoor temperature sensor shortcircuited

Discharge pipe temperature sensor open

Discharge pipe temperature sensor shortcircuited

Outdoor high pressure abnormal

Discharge pipe temperature abnormal

Model abnormal

Indoor fan abnormal

Outdoor signal abnormal

Outdoor EEPROM abnormal

1. REMOTE  CONTROLLER

ARG36ELC3 / AOG36EPA3L

ARG45ELC3 / AOG45EPA3L

ARY36ELC3 / AOY36EPA3L

ARY45ELC3 / AOY45EPA3L

E R R O R     C O N T E N T S

- 6 -

2003.09.22

Summary of Contents for AOG36EPA3L

Page 1: ...PA3L ARG45ELC3 A ARY45ELC3 AOY45EPA3L OG45EPA3L C O N T E N T S SPECIFICATIONS 1 OUTLINE AND DIMENSIONS 2 CIRCUIT DIAGRAM 3 REFRIGERANT SYSTEM DIAGRAM 4 INDOOR PRINTED CIRCUIT BOARD CIRCUIT DIAGRAM 5 DISASSEMBLY ILLUSTRATION 7 ERROR CONTENTS 6 PARTS LIST 14 ACCESSORIES 16 ARY36ELC3 AOY36EPA3L ...

Page 2: ...1 200 OUTDOOR UNIT TYPE MFB 362FT HI SPEED r p m 790 INDOOR UNIT H x W x D mm 270 x 1 210 x 700 OUTDOOR UNIT 1 152 x 940 x 370 INDOOR UNIT NET GROSS kg 45 60 OUTDOOR UNIT 94 108 102 116 S P E C I F I C A T I O N S ELECTRICAL DATA COMPRESSOR FAN MOTOR DIMENSIONS WEIGHTS Note The above list shows values at the external static pressure of 10 mm Aq 98 Pa 1 2003 09 22 PIPE LENGTH MODELS 10 m 33 ft 2 30...

Page 3: ... 2 2003 09 22 ...

Page 4: ...ER COMPRESSOR FAN CAPACITOR FUSE 5A TERMINAL TO POWER SUPPLY TO INDOOR UNIT MAGNETIC RELAY CR COMPOSITE CRANKCASE HEATER THERMOSTAT DISCHARGE PIPE R CONNECTOR WHITE WHITE BLUE BLUE BLACK BLACK BLACK GREEN YELLOW BLACK BLACK T1 T3 T2 2 WHITE GRAY WHITE BLACK WHITE BROWN BLUE RED BLUE BLUE 4 6 32 A A1 1 3 5 31 B A2 S T N 3 2 N 1 WHITE RED INTERNAL OVERLOAD PROTECTOR FAN MOTOR CAPACITOR 10 0 µF 15 0 ...

Page 5: ...ILLARY TUBE Charging valve COMPRESSOR ACCUMULATOR Charging valve DRYER OUTDOOR UNIT INDOOR UNIT EVAPORATOR CONDENSER Models ARG45ELC3 AOG45EPA3L ARY45ELC3 AOY45EPA3L Refrigerant pipe 19 05mm 3 4 Refrigerant pipe 9 53mm 3 8 CAPILLARY TUBE Charging valve COMPRESSOR ACCUMULATOR Charging valve DRYER OUTDOOR UNIT INDOOR UNIT EVAPORATOR CONDENSER O O O 4 2003 09 22 ...

Page 6: ... 5 2003 09 22 ...

Page 7: ...T START STOP CLOCK ADJUST SET TIME TEMP DAY FAN CONTROL MASTER CONTROL 2 1 DAY OFF ENERGY SAVE ENERGY SAVE ZONE Stop operation Table 1 Error cord Error contents Communication error indoor unit remote controller Communication error indoor unit outdoor unit Room temperature sensor open Room temperature sensor shortcircuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperat...

Page 8: ...373 7 2003 09 22 Models AOG36EPA3L AOY36EPA3L AOG45EPA3L AOY45EPA3L ...

Page 9: ... 8 2003 09 22 Models AOG36EPA3L AOY36EPA3L ...

Page 10: ... 9 2003 09 22 Models AOG45EPA3L AOY45EPA3L ...

Page 11: ...791 36 34 823 2 824 4 32 549 401 407 815 880 1 10 2003 09 22 Models AOG36EPA3L AOY36EPA3L AOG45EPA3L AOY45EPA3L ...

Page 12: ...574 2 574 1 11 2003 09 22 Models ARG36ELC3 ARY36ELC3 ARG45ELC3 ARY36ELC3 ...

Page 13: ... 12 2003 09 22 Models ARG36ELC3 ARY36ELC3 ARG45ELC3 ARY45ELC3 ...

Page 14: ...361271706 195 Clamp SKB 100 313361275805 313361275805 196 1 Clamp SKB 3M 312300787605 312300787605 INDOOR UNIT Ref No Ord Q ty 234 Thermistor Assy 9703299056 9703299056 235 Thermistor Assy Pipe 9703297045 9703297045 236 Controller PCB Assy 9704557056 9704557056 240 Remote Control Unit 9703173066 9703173066 287 Cap Power 9352173011 9352173011 324 Top Plate 9356546002 9356546002 329 Coupling Pipe As...

Page 15: ... 9364178004 9364060002 320 Wire Clamp Metal 313483219905 313483219905 333 2 Accumulator B 9301942019 9368463007 334 Suction Pipe B 9364065007 9362557009 34 Capacitor Fan Motor 9357965024 9357965024 15 2003 09 22 Ord Q ty 361 Accumulator Support Assy 9355351003 401 Terminal 2P 9701971015 9701971015 405 Clamp No 1763 313816345304 313816345304 407 Clip Cable No 1259 313739340109 313739340109 450 Disc...

Page 16: ...Models ARG36ELC3 ARG45ELC3 ARY36ELC3 ARY45ELC3 13 2003 09 22 ...

Page 17: ...mote control unit cord clamp For wiring conduit gas side connection Insulates the drain hose and vinyl hose connection 9357036007 9356563009 313005446653 313005446759 9350716029 9352766015 312300787605 9703173066 313714181904 301141153027 9357038001 313806217708 INDOOR UNIT ACCES S ORIES 1 1 1 2 1 1 1 Name and S hape Q ty Application Parts No Power cap Auxiliary pipe assembly Edge cover Tapping sc...

Page 18: ...0308G2351 ...

Reviews: