OUTDOOR
UNIT
AO
A12-14L
OUTDOOR
UNIT
AO
A12-14L
6. ADDITIONAL CHARGE CALCULATION
MODEL : AO A12L
REFRIGERANT CHARGE
MODEL : AO A14L
REFRIGERANT CHARGE
Refrigerant amount
g
Pipe length
m
15
20
25
Additional charge
g
0 (Chargeless)
+100
+200
Refrigerant amount
g
Pipe length
m
15
20
25
Additional charge
g
0 (Chargeless)
+100
+200
Refrigerant type
Refrigerant type
20g/m
1250
R410A
1150
20g/m
R410A
- (02 - 07) -