![Fujitsu AO*S09LDC User Manual Download Page 26](http://html.mh-extra.com/html/fujitsu/ao-s09ldc/ao-s09ldc_user-manual_2344008026.webp)
- (02 - 02) -
OUTDOOR
UNIT
AO
S09-18LD
OUTDOOR
UNIT
AO
S09-18LD
INVERTER HEAT PUMP
AO S18LDC
230V 50Hz
198 - 264V 50Hz
A
7.7
2,000
1,910
Propeller fan × 1
W
30
50
50
546 × 876 × 36.4
1.3
2 × 26
Copper
Aluminium
Rotary × 1
W
1,100
R410A
g
1,150
POE(VG74)
Steel
Beige
578 × 790 × 300
648 × 910 × 380
40 (88)
44 (97)
6.35 ( 1/4 in.)
12.7 ( 1/2 in.)
Flare
20(chargeless:15)
15
-10 to 43
-15 to 24
Note :
Specifications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB/19°CWB. and outdoor temperature of 35°CDB/24°CWB.
Heating : Indoor temperature of 20°CDB/15°CWB. and outdoor temperature of 7°CDB/6°CWB.
Pipe length : 7.5 m, Height difference : 0 m. (Outdoor unit - Indoor unit)
Cooling
Heating
Colour
Net
Gross
Net
Type
Charge
Type
Material
Motor output
Cooling
Heating
Dimensions (H × W × D)
Type
Model name
Power source
Available voltage range
m
Connection pipe
Size
mm
Liquid
Gas
Method
Max. length
Max. height difference
Compressor
Refrigerant
Sound pressure level
Starting current
Cooling
Heating
Type × Q'ty
Refrigerant oil
Enclosure
Heat exchanger type
Fin pitch
Rows × Stages
Pipe type
Fin type
Type × Q'ty
Motor output
mm
Weight
kg(lb.)
Dimensions
(H × W × D)
Gross
°C
Operation range
Fan
Airflow
rate
m
3
/h
dB(A)
mm
Summary of Contents for AO*S09LDC
Page 1: ...AS B09LDC AS B12LDC AS B18LDC R410A D1D_AS011E 03 2008 02 20 1 WALL MOUNTED TYPE INDOOR UNIT ...
Page 24: ...R410A D1D_AO012E 02 2007 11 26 AO S09LDC AO S12LDC AO S18LDC 2 SINGLE TYPE OUTDOOR UNIT ...
Page 39: ... 02 15 OUTDOOR UNIT AO S09 18LD OUTDOOR UNIT AO S09 18LD 8 2 SOUND LEVEL CHECK POINT ...