Height difference H
1 Indoor unit is upper than outdoor unit.
2 Indoor unit is under than outdoor unit.
Indoor unit
Indoor unit
Connection pipe
Outdoor unit
Outdoor unit
Connection pipe
HEATING
Pipe length (m)
5
7.5
10
15
Height difference H
(m)
Û
1
Indoor unit is upper
than outdoor unit.
10
-
-
0.908
0.875
7.5
-
0.954
0.908
0.875
5
1.000
0.954
0.908
0.875
0
1.000
0.954
0.908
0.875
Û
2
Indoor unit is under
than outdoor unit
-5
0.995
0.949
0.903
0.870
-7.5
-
0.947
0.902
0.868
-10
-
-
0.900
0.867
COOLING
Pipe length (m)
5
7.5
10
15
Height difference H
(m)
Û
1
Indoor unit is upper
than outdoor unit.
10
-
-
0.957
0.911
7.5
-
0.974
0.961
0.916
5
0.992
0.978
0.965
0.919
0
1.000
0.986
0.972
0.927
Û
2
Indoor unit is under
than outdoor unit
-5
1.000
0.986
0.972
0.927
-7.5
-
0.986
0.972
0.927
-10
-
-
0.972
0.927