background image

En-1

SAFETY PRECAUTIONS

 

Before using the appliance, read these “PRECAUTIONS” thoroughly 

and operate in the correct way.

 

The instructions in this section all relate to safety; be sure to maintain 

safe operating conditions.

 

“WARNING” and “CAUTION” have the following meanings in these 

instructions:

 WARNING

This mark indicates procedures which, if im-

properly performed, might lead to the death or 

serious injury of the user.

 CAUTION

This mark indicates procedures which, if im-

properly performed, might possibly result in per-

sonal harm to the user, or damage to property.

PRECAUTIONS ON USE

 WARNING

 

Do not keep exposing oneself to the direct wind of air conditioner for a 

long time.

 

● Do not insert fingers or objects into the outlet port or intake grilles.

 

Except for EMERGENCY, never turn off main as well as sub breaker 

of the indoor units during operation. It will cause compressor failure as 

well as water leakage. First, stop the indoor unit by operating the con-

trol unit, converter or external input device and then cut the breaker. 

Make sure to operate through the control unit, converter or external 

input device.

 

If the power supply cord of this appliance is damaged, it should only 

be replaced by the authorized service personal, since special purpose 

tools and specified cord are required.

 

● If any refrigerant happens to leak, extinguish any flames, ventilate the 

room and get in touch with authorized service personnel.

 CAUTION

 

● Do not place animals or plants in the direct path of the airflow.

 

● Do not direct airflow at fireplaces or heating apparatus.

 

Do not block or cover the inlet port and outlet port.

 

Do not climb on, or place objects on, the air conditioner.

 

● Do not set flower vases or water containers on top of air conditioners.

 

Do not hang objects from the indoor unit.

 

Do not place anything below the indoor unit that should not get wet.

 

Always turn off the electrical breaker whenever cleaning the air condi-

tioner or the air filter.

 

Do not pour water or cleaning solvent on the unit directly, or wash the 

unit with them.

 

Do not expose the air conditioner directly to water.

 

Do not operate the air conditioner with wet hands.

 

Check the condition of the installation stand for damage.

 

● Operate only with air filters installed.

 

Do not drink the water drained from the air conditioner.

 

● Do not apply any heavy pressure to radiator fins.

 

● Do not use inflammable gases near the air conditioner.

 

Do not touch the piping during operation.

 

Ensure that any electronic equipment is at least 1 m away from either 

the indoor or outdoor units.

 

This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of ex-

perience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for 

their safety. Children should be supervised to ensure that they do not 

play with the appliance.

Note:

Switching the operating mode in the heat recovery system may require 

some time to prepare for operation. Please note that this is not a fault.

PRECAUTIONS ON INSTALLATION

 CAUTION

 

Do not attempt to install this air conditioner by yourself.

 

This unit contains no user-serviceable parts. Always consult authorized 

service personnel for repairs.

 

When moving, consult authorized service personnel for disconnection 

and installation of the unit.

 

The unit must be grounded.

 

Make sure drain work is implemented properly for drainage.

 

● Avoid installing the air conditioner near a fireplace or other heating 

apparatus.

 

When installing the indoor and outdoor units, take precautions to pre-

vent access by infants.

NAME OF PARTS

(2)

(1)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(5)

(6)

(7)

(8)

(9)

(1) Air Filter
(2) 

Airflow Direction Flaps

(3) Air Intake Grille
(4) Operating Control Panel and Indicator Lamps
(5) FILTER Indicator Lamp (Red): Lights on when it is time to clean the 

filter. Clean the filter according to “CLEANING AND CARE”. Lights off 

when the RESET button is pressed after cleaning.

(6) TIMER Indicator Lamp (Orange): It lights on while timer is working.
(7) OPERATION Indicator Lamp (Green): It lights on while operating.
(8) Remote Control Signal Receiver: This is the place to receive the 

signals from the remote controller.

(9) MANUAL AUTO button: This is used to operate it while remote con-

troller is not available.

Control unit (optional)

Types of remote controllers:

● Wireless remote controller

● Wired remote controller

● Simple remote controller

For operation method, please refer to the Operating Manual of each 

device.

CONTENTS

SAFETY PRECAUTIONS ........................................................................ 1

NAME OF PARTS ................................................................................... 1

MANUAL AUTO OPERATION ................................................................ 2

ADJUSTING THE DIRECTION OF AIR CIRCULATION ......................... 2

OPERATING TIPS .................................................................................. 2

CLEANING AND CARE........................................................................... 2

TROUBLESHOOTING ............................................................................ 3

SPECIFICATIONS ................................................................................... 4

OPERATING MANUAL

PART No. 9369313325

VRF system indoor unit (Cassette type)

9369313325-01_OM.indb   1

2/7/2019   18:29:00

Summary of Contents for AIRSTAGE AUXB004GLEH

Page 1: ...ra ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Τύπος κασέτας Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά MANUAL DE FUNCIONAMENTO UNIDADE INTERIOR Tipo cassete Guarde este manual para consulta futura РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ кассетного типа Сохраните данное руководство для последующего использования KULLANIM KILAVUZU İÇ ÜNİTE Kaset tipi Bu kılavuzu ileride başvurmak üzere...

Page 2: ... Do not apply any heavy pressure to radiator fins Do not use inflammable gases near the air conditioner Do not touch the piping during operation Ensure that any electronic equipment is at least 1 m away from either the indoor or outdoor units This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of ex perience and knowledg...

Page 3: ...ioner until the room is heated Microcomputer controlled automatic defrosting When using the Heating mode under conditions of low outdoor air temperature high humidity frost may form on the outdoor unit result ing in reduced operating performance In order to prevent this kind of reduced performance this unit is equipped with a Microcomputer con trolled automatic defrosting function If frost forms t...

Page 4: ...ound becomes loud These are the sounds of the flowing of refrigerant When operation starts When oil recovery operation finishes When automatic defrosting operation finishes During operation a slight squeaking sound may be heard This is the result of minute expansion and contraction of the panel due to tem perature changes During Heating operation a sizzling sound may be heard occasionally This sou...

Page 5: ...paratus and com puters inside the room or are there too many people in the room Is the fan speed set to low Set the temperature lower than the room temperature and use it Temperature does not fall down well Temperature may not fall down depending on the room conditions While high humidity or the room temperature is high See page 2 In the following situations stop operation immediately and get in t...

Page 6: ...10_9369313325_OM_Ar indd 5 10_9369313325_OM_Ar indd 5 2 7 2019 18 33 03 2 7 2019 18 33 03 ...

Reviews: