The following conditions may not be breakdowns so 
check again.

Doesn’t operate at all:

 

Has there been a power failure?

 

Has a fuse blown out, or a circuit breaker been tripped?

 

Is the main power switch set to the OFF position?

 

Are you trying to engage in an operation different from the priority 
state? (See page 3)

 

Is it in standby state? (See page 3)

 

Is the Auto off operation of the Human sensor setting active? (See 
page 2)

The operation mode cannot be changed:

 

Are you trying to change to an operation different from the priority 
conditions? (See page 3)

Poor Cooling (or Heating) performance:

 

Did you adjust the room temperature settings (thermostat) correctly?

 

Is the air 

fi

 lter dirty? (See page 4)

 

Are the air conditioner’s inlet port or outlet port blocked?

 

Is there a window or door open?

 

In the case of Cooling operation, is a window allowing bright sunlight to 
enter? (Close the curtains.)

 

In the case of Cooling operation, are there heating apparatus and com-
puters inside the room, or are there too many people in the room?

 

Is the fan speed set to low?

 

Is the Auto saving operation of the Human sensor setting active? (See 
page 2)

Set the temperature lower than the room temperature and use it:

 

Temperature does not fall down well. 
Temperature may not fall down depending on the room conditions. 
(While high humidity or the room temperature is high.) (See page 3)

In following situations stop operation immediately and 
get in touch with authorized service personnel.

 

The problem cannot be solved even when the troubleshooting checks 
have been performed.

 

The FILTER indicator lamp (red) is 

fl

 ashing very fast.

 

The wired remote controller or simple remote controller indicate Er 
(when connected).

 

It has burning smell.

SPECIFICATIONS

MODEL

AS*A012GCEH AS*A014GCEH AS*E012GCEH AS*E014GCEH

POWER SOURCE

220-240V ~ 50Hz, 230V ~ 60Hz

AVAILABLE 
VOLTAGE RANGE

198 to 264 V (50Hz)
198 to 253 V (60Hz)

COOLING 
CAPACITY

[kW]

3.6

4.0

3.6

4.0

[Btu/h]

12,300

13,600

12,300

13,600

HEATING 
CAPACITY

[kW]

4.0

4.5

4.0

4.5

[Btu/h]

13,600

15,400

13,600

15,400

INPUT 
POWER

[W]

25

36

25

36

CURRENT

[A]

0.25

0.30

0.25

0.30

SOUND PRESSURE LEVEL

HIGH

dB [A]

40

44

40

44

MED - HIGH dB [A]

37

42

37

42

MED

dB [A]

35

40

35

40

MED - LOW dB [A]

33

37

33

37

LOW

dB [A]

30

34

30

34

QUIET

dB [A]

24

24

24

24

DIMENSIONS & WEIGHT

HEIGHT

[mm]

268

WIDTH

[mm]

840

DEPTH

[mm]

203

WEIGHT

[kg]

8.5

*1: This value is “cooling operation/heating operation”.

 

 Acoustic Noise Information: 
The maximum sound pressure level is less than 70 dB (A) for both 
indoor unit and outdoor unit. According IEC 704-1 and ISO 3744.

 

This product contains 

fl

 uorinated greenhouse gases.

9377772404_OM_9L.indb   6

9377772404_OM_9L.indb   6

2019/2/1   13:55:37

2019/2/1   13:55:37

Summary of Contents for Airstage AS A012GCEH

Page 1: ...ieses Handbuch für eine spätere Bezugnahme auf MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo montato a parete Conservare questo manuale per consultazione futura ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Επιτοιχιος τύπος Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ настенного типа Сохраните данное руководство для последующего использования KULLANIM KI...

Page 2: ... if im properly performed might lead to the death or serious injury of the user CAUTION This mark indicates procedures which if im properly performed might possibly result in per sonal harm to the user or damage to property PRECAUTIONS ON USE WARNING Do not keep exposing oneself to the direct wind of air conditioner for a long time Do not insert fingers or objects into the outlet port or intake gr...

Page 3: ...same system doesn t operate the air conditioner will operate in cooling Fan speed AUTO Setting temperature 23 C Stopping Operation Press the MANUAL AUTO button on the operating control panel AIRFLOW DIRECTION Vertical airflow direction The vertical wind direc tion can be controlled with the remote control ler Cooling and Dry Heating 1 2 3 4 1 2 3 4 Horizontal airflow direction The horizontal airfl...

Page 4: ...by using a soft cloth NOTES Energy Saving function may not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation Since the Human sensor detects infrared light given out by people there may be cases where this detection is incorrect Situations in which the sensor will detect no people in the room ev...

Page 5: ...d c a b b a c 3 Filter holder and air cleaning filter are attached on the rear side of the air filter Remove them from the air filter by unlatching each corner of the filter holder d d d d d 4 Remove dust by using a vacuum cleaner or by washing the filter When you wash the filter use neutral household detergent and warm water After rinse the filter well dry it thoroughly in a shaded place before y...

Page 6: ... may temporarily stop to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit s fan will stop If you wish to warm the room further set the thermostat for a higher setting During oil recovery operation the airflow may stop for approximately 10 minutes See page 3 During Heating operation the...

Page 7: ...ll Temperature may not fall down depending on the room conditions While high humidity or the room temperature is high See page 3 In following situations stop operation immediately and get in touch with authorized service personnel The problem cannot be solved even when the troubleshooting checks have been performed The FILTER indicator lamp red is flashing very fast The wired remote controller or ...

Page 8: ...9377772404_OM_Ar indd 7 9377772404_OM_Ar indd 7 2019 2 1 13 55 27 2019 2 1 13 55 27 ...