background image

En-2

(1)  Intake grille
(2)  MANUAL AUTO button: This is used to operate it while remote 

controller is not available.

(3)  Front panel
(4)  Human censor
(5)  Vertical air

fl

 ow direction louver

(6)  Power diffuser
(7)  Remote Control Signal Receiver: This is the place to receive the 

signals from the remote controller.

(8)  FILTER Indicator Lamp (red): It lights on if the 

fi

 lter became dirty. 

Clean the 

fi

 lter referring to “CLEANING AND CARE”. It lights off 

when RESET button is pressed after cleaning.

(9)  TIMER Indicator Lamp (orange): It lights on while timer is working.
(10)  OPERATION Indicator Lamp (green): It lights on while operating.
(11)  Drain Hose
(12)  Air cleaning 

fi

 lter

(13)  Air Filter
(14)  Horizontal air

fl

 ow direction louver (behind Vertical air

fl

 ow direction 

louver)

Control unit (optional)

Types of remote controllers:

 

Wireless remote controller

 

Wired remote controller

 

Simple remote controller

For operation method, please refer to the Operating Manual of each 
device.

MANUAL AUTO OPERATION

Use the MANUAL AUTO operation in the event the remote control unit is 
lost or otherwise unavailable.

 CAUTION

Do not press the MANUAL AUTO button with wet hands or pointed ob-
jects, otherwise an electric shock or malfunction may occur.

Starting Operation

Press the MANUAL AUTO button on the operating 
control panel.

The operation can be set in the following setting.

Operating mode

AUTO:
When Auto mode cannot be selected, it will 
operate in the same mode as the other indoor 
unit in the same system. (When other indoor 
unit in the same system doesn’t operate, the air 
conditioner will operate in cooling.)

Fan speed

AUTO

Setting temperature

23 °C

Stopping Operation

Press the MANUAL AUTO button on the operating 
control panel.

AIRFLOW DIRECTION

Vertical air

fl

 ow direction

The vertical wind direc-
tion can be controlled 
with the remote control-
ler.

Cooling and Dry

Heating

1

2

3

4

1

2

3

4

Horizontal air

fl

 ow direction

The horizontal 
air

fl

 ow direction can 

be manually set by 
adjusting Horizontal 
air

fl

 ow direction 

louvers.

Knob (2 places) 

Louvers

Knob

HUMAN SENSOR

About the human sensor

The Human sensor detects whether there are people in the room by 
looking for movement by people in the room.

Setting of Human sensor can be done in the remote controller of the fol-
lowing. Refer to the operating manual of the remote controller.

 

UTY-RNR*Z* (wired remote controller)

About the Auto saving operation

If no one enters the room during the set time (15, 30, 60, 90, 120, 180 
minutes), the set temperature will be automatically controlled.

(When someone comes back into the room, the Human sensor will de-
tect this, and automatically revert to the original settings.)

About the Auto off operation

If no one enters the room during the set time (1 to 24 hours in 1 hour 
increments), the air conditioner will automatically stop operation.

NOTES:

 

To restart operation, press the [On/Off] button of the remote controller.

 

The Auto off operation may not operate even if there is no one in the 
room. The sensor may incorrectly detect people even if there is no one 
in the room.

Application range

Vertical angle 90° (Side view)

Horizontal angle 100° (Top view)

90°

7 m

50°

50°

7 m

9377772404_OM_9L.indb   2

9377772404_OM_9L.indb   2

2019/2/1   13:55:36

2019/2/1   13:55:36

Summary of Contents for Airstage AS A012GCEH

Page 1: ...ieses Handbuch für eine spätere Bezugnahme auf MANUALE DI ISTRUZIONI UNITÀ INTERNA tipo montato a parete Conservare questo manuale per consultazione futura ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ ΕΣΩΤΕΡΙΚΗ ΜΟΝΑΔΑ Επιτοιχιος τύπος Διατηρήστε το παρόν εγχειρίδιο για μελλοντική αναφορά РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ ВНУТРЕННИЙ МОДУЛЬ настенного типа Сохраните данное руководство для последующего использования KULLANIM KI...

Page 2: ... if im properly performed might lead to the death or serious injury of the user CAUTION This mark indicates procedures which if im properly performed might possibly result in per sonal harm to the user or damage to property PRECAUTIONS ON USE WARNING Do not keep exposing oneself to the direct wind of air conditioner for a long time Do not insert fingers or objects into the outlet port or intake gr...

Page 3: ...same system doesn t operate the air conditioner will operate in cooling Fan speed AUTO Setting temperature 23 C Stopping Operation Press the MANUAL AUTO button on the operating control panel AIRFLOW DIRECTION Vertical airflow direction The vertical wind direc tion can be controlled with the remote control ler Cooling and Dry Heating 1 2 3 4 1 2 3 4 Horizontal airflow direction The horizontal airfl...

Page 4: ...by using a soft cloth NOTES Energy Saving function may not work when the room temperature is very different from the temperature defined in temperature setting such as when immediately after starting the operation Since the Human sensor detects infrared light given out by people there may be cases where this detection is incorrect Situations in which the sensor will detect no people in the room ev...

Page 5: ...d c a b b a c 3 Filter holder and air cleaning filter are attached on the rear side of the air filter Remove them from the air filter by unlatching each corner of the filter holder d d d d d 4 Remove dust by using a vacuum cleaner or by washing the filter When you wash the filter use neutral household detergent and warm water After rinse the filter well dry it thoroughly in a shaded place before y...

Page 6: ... may temporarily stop to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor unit s fan will stop If you wish to warm the room further set the thermostat for a higher setting During oil recovery operation the airflow may stop for approximately 10 minutes See page 3 During Heating operation the...

Page 7: ...ll Temperature may not fall down depending on the room conditions While high humidity or the room temperature is high See page 3 In following situations stop operation immediately and get in touch with authorized service personnel The problem cannot be solved even when the troubleshooting checks have been performed The FILTER indicator lamp red is flashing very fast The wired remote controller or ...

Page 8: ...9377772404_OM_Ar indd 7 9377772404_OM_Ar indd 7 2019 2 1 13 55 27 2019 2 1 13 55 27 ...

Reviews: