4-2. Models: AOYG12KVCBN and AOYG14KVCBN
2-Way
valve
Strainer
Strainer
3-Way
valve
Muffler
Muffler
4-Way valve
Expansion valve
Heat exchanger
( INDOOR )
Heat exchanger
( OUTDOOR )
C
o
mp
re
sso
r
Cooling
Heating
Th
D
Th
R
Th
P
Th
HO
Th
O
: Thermistor (Discharge Temp.)
: Thermistor (Outdoor Temp.)
: Thermistor (Heat Exchanger Out Temp.)
Th
D
Th
O
Th
HO
: Thermistor (Room Temp.)
: Thermistor (Pipe Temp.)
Th
R
Th
P
Pressure
switch
- 44 -
4-2. Models: AOYG12KVCBN and AOYG14KVCBN
4. Refrigerant circuit
OUTDOOR UNIT
AOYG09-14KVCBN
OUTDOOR UNIT
AOYG09-14KVCBN