6-2. Models: AOYG12KVCBN and AOYG14KVCBN
NOTE:
Values mentioned in the table are calculated based on the maximum capacity.
COOLING
Pipe length (m)
5
7.5
10
15
20
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
15
—
—
—
0.951
0.950
10
—
—
0.979
0.967
0.966
7.5
—
0.988
0.983
0.971
0.970
5
0.994
0.992
0.987
0.975
0.974
0
1.002
1.000
0.995
0.983
0.982
Indoor unit is lower than
outdoor unit *2
-5
1.002
1.000
0.995
0.983
0.982
-7.5
—
1.000
0.995
0.983
0.982
-10
—
—
0.995
0.983
0.982
-15
—
—
—
0.983
0.982
HEATING
Pipe length (m)
5
7.5
10
15
20
Height difference H (m)
Indoor unit is higher than
outdoor unit *1
15
—
—
—
0.994
0.979
10
—
—
1.012
0.994
0.979
7.5
—
1.000
1.012
0.994
0.979
5
0.969
1.000
1.012
0.994
0.979
0
0.969
1.000
1.012
0.994
0.979
Indoor unit is lower than
outdoor unit *2
-5
0.964
0.995
1.007
0.989
0.974
-7.5
—
0.993
1.004
0.986
0.972
-10
—
—
1.002
0.984
0.969
-15
—
—
—
0.974
0.959
- 47 -
6-2. Models: AOYG12KVCBN and AOYG14KVCBN
6. Capacity compensation rate for pipe length and height difference
OUTDOOR UNIT
AOYG09-14KVCBN
OUTDOOR UNIT
AOYG09-14KVCBN