En-15

TROUBLESHOOTING

Instructions relating to heating (*) are applicable only to “HEAT & COOL MODEL” (Reverse Cycle).

In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the elec-
trical breaker, and consult authorized service personnel.
Merely turning off the unit’s power switch will not completely disconnect the unit from the power
source. Always be sure to turn off the electrical breaker to ensure that power is completely off.

Before requesting service, perform the following checks:

WARNING!

Symptom

Doesn’t operate immedi-
ately:

Noise is heard:

Odor:

Mist or steam are
emitted:

Airflow is weak or stops:

Water is produced from
the outdoor unit:

Problem

If the unit is stopped and then immediately started again, the com-
pressor will not operate for about 3 minutes, in order to prevent
fuse blowouts.

Whenever the power switch is turned off then on again, the pro-
tection circuit will operate for about 3 minutes, preventing unit
operation during that period.

During operation and immediately after stopping the unit, the
sound of water flowing in the air conditioner’s piping may be
heard. Also, noise may be particularly noticeable for about 2 to 3
minutes after starting operation (sound of coolant flowing).

During operation, a slight squeaking sound may be heard. This is
the result of minute expansion and contraction of the front cover
due to temperature changes.

*

During Heating operation, a swoosh sound may be heard occa-
sionally. This sound is produced by the Automatic Defrosting op-
eration.

Occasionally an odor may be emitted from the indoor unit. This
may be the result of room odor (furniture, tobacco, etc.) which
have been taken into the air conditioner.

During Cooling or Dry operation, a thin mist may be seen emitted
from the indoor unit. This results from the sudden Cooling of
room air by the air emitted from the air conditioner, resulting in
condensation and misting.

*

During Heating operation, the outdoor unit’s fan may stop, and
steam may be seen rising from the unit. This is due to Automatic
Defrosting operation.

*

When Heating operation is started, fan speed is temporarily very
low, to allow internal parts to warm up.

*

During Heating operation, if the room temperature rises above
the thermostat setting, the outdoor unit will stop, and the indoor
unit will operate at very low fan speed. If you wish to warm the
room further, set the thermostat for a higher setting.

*

During Heating operation, the unit will temporarily stop opera-
tion (between 7 and 15 minutes) as the Automatic Defrosting mode
operates. During Automatic Defrosting operation, the OPERATION
indicator light will flash.

The fan may operate at very low speed during Dry operation or
when the unit is monitoring the room’s temperature.

In the monitor AUTO operation, the fan will operate at very low
speed.

*

During Heating operation, water may be produced by the out-
door unit due to Automatic Defrosting operation.

See Page

16

16

16

7

7

16

NORMAL

FUNCTION

Summary of Contents for ABU30

Page 1: ......

Page 2: ...ning the air conditioner or chang ing the air filter Connection valves become hot during Heating handle with care Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Do not drink the water drained from...

Page 3: ...EAT COOL MODEL REVERSE CYCLE When the SLEEP timer button is pressed during Heating mode the air conditioner s thermostat setting is gradu ally lowered during the period of operation during Cool ing or Dry mode the thermostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTR...

Page 4: ...ENERGY SAVE HEAT ON A AUTO HIGH MED LOW C F G H I J R U V W X Y S T K L M N O P D E Q CLOCK COOL AUTO PM AM Instructions relating to heating are applicable only to HEAT COOL MODEL Reverse Cycle NAME OF PARTS Fig 5 Fig 1 Fig 4 Fig 2 Fig 3 Fig 6 Fig 7 Electrical Breaker This breaker is installed during the electrical installation SWING SWING TIMER OPERATION MANUAL AUTO 3 4 5 6 7 2 1 A A B 9 8 0 ...

Page 5: ...will begin to flash simultaneously To stop the test operation mode either press the TEST RUN button once again or press the START STOP button to stop the air conditioner P ACL Button Q Remote Control Unit Display Fig 7 R Transmit Indicator S Clock Display T Operating Mode Display U Timer Mode Display V Fan Speed Display W Temperature Set Display X Timer Set Indicator Y Temperature Set Indicator Fi...

Page 6: ... no beep is heard press the remote control unit button again Remote Control Unit Holder For Hand Held Use CAUTION Take care to prevent infants from accidentally swallowing batteries When not using the remote control unit for an extended period remove the batteries to avoid possible leakage and damage to the unit If leaking battery fluid comes in contact with your skin eyes or mouth immedi ately wa...

Page 7: ...tandard value and may differ somewhat from the actual room temperature To Set the Fan Speed Press the FAN CONTROL button Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warm air However the fan will operate at very low speed wh...

Page 8: ... of the room and accordingly selects the proper operation mode When the air conditioner has adjusted your room s temperature to near the ther mostat setting it will begin monitor operation In the monitor operation mode the fan will operate at low speed If the room temperature subsequently changes the air conditioner will once again select the appropriate operation Heating Cool ing to adjust the te...

Page 9: ...play will alternately show OFF timer and ON timer then change to show the time setting for the operation to occur first The PROGRAM timer will begin operation If the ON timer has been selected to operate first the unit will stop operating at this point About five seconds later the entire display will reappear c c c d SLEEP TIMER SET TIME SET TEMP MASTER CONTROL FAN CONTROL TIMER ON To Cancel the T...

Page 10: ... the indoor unit s OPERATION indicator light red and the TIMER indicator light green will turn on To Change the Timer Settings Press the SLEEP button once again and set the time using the SET TIME buttons Set the time while the Timer Mode Display is flashing the flashing will continue for about five seconds button Press to advance the time button Press to reverse the time About five seconds later ...

Page 11: ...izontal Air Direction Adjustment Press the AIR FLOW DIRECTION HORIZONTAL SET button Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 The remote control unit s display does not change Use the air direction adjustments within the ranges shown above Fig 9 DANGER Never place fingers or foreign objects inside the outlet port could cause personal injury Always use...

Page 12: ...e Heating range 4 to 5 for long periods of time since water vapor may con dense near the outlet port and drops of water may drip from the air conditioner To select Horizontal Airflow SWING Operation Press the AIR FLOW DIRECTION HORIZONTAL SWING button The SWING indicator light HORIZONTAL SWING orange will turn on In this mode the RIGHT LEFT air direction louvers will swing automatically to direct ...

Page 13: ...t temperature setting increases by 2 F as soon as the ENERGY SAVE button is pressed and then increases by another 2 F after one hour has passed In this manner energy is saved by continuing to cool or dry at a thermostat temperature of 4 F more than the setting ENERGY SAVE setting To Cancel the ENERGY SAVE Press the ENERGY SAVE button About the ENERGY SAVE MANUAL AUTO OPERATION Use the MANUAL AUTO ...

Page 14: ...ull the air filters upward to remove them Remove the air filters by raising its handle while pulling it out towards you 2 Clean the air filters Remove the dust from the air filters by vacuuming or washing them After washing allow the air filters to dry thoroughly in an area protected from sunlight Air filter When used for extended periods the unit may accumulate dirt inside reducing its performanc...

Page 15: ...perature changes During Heating operation a swoosh sound may be heard occa sionally This sound is produced by the Automatic Defrosting op eration Occasionally an odor may be emitted from the indoor unit This may be the result of room odor furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This re...

Page 16: ...Cycle Operation and Performance Heating Performance This air conditioner operates on the heat pump principle absorbing heat from outdoor air and transferring that heat indoors As a result the operating performance is reduced as outdoor air temperature drops If you feel that insuffi cient heating performance is being produced we recom mend you use this air conditioner in conjunction with another ki...

Page 17: ...the unit is used for long pe riods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects un derneath Heating Mode About 32 to 75 F About 86 F or less Outdoor temperature Indoor temperature Indoor humidity COOLING MODEL HEAT COOL MODEL Reverse Cycle Temperature and Humidity Range If the air conditioner is operated under highe...

Page 18: ......