![Fujitsu AB*14LBAJ Service Instruction Download Page 92](http://html.mh-extra.com/html/fujitsu/ab-14lbaj/ab-14lbaj_service-instruction_118000092.webp)
SERVICE PARTS INFORMATION 5
Check Point : AB*14/ 18/ 24LBAJ
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
445
8%
346
8%
124
8%
80.0
8%
80.0
8%
Resistance value
(AC)
Thermal protector
Pr
VIOLET
BLUE
PINK
RED
BLACK
WHITE
140°C
at 20°C
Indoor Unit Fan Motor
Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
02-54
AB*14LBAJ
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
222
8%
175
8%
279
8%
63.5
8%
63.5
8%
Resistance value
at 20°C
AB*24LBAJ
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
291
8%
204
8%
182
8%
78.5
8%
78.5
8%
Resistance value
at 20°C
AB*18LBAJ
Check Point : AR*9LUAB/ 12/ 14/ 18/ 22LUAD
(AC)
Thermal protector
Pr
VIOLET
BLUE
PINK
RED
BLACK
WHITE
150°C
Check each winding resistance of the motor
If Resistance value is abnormal, replace motor.
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
90.3
8%
152
8%
222
8%
42.9
8%
42.9
8%
Resistance value
at 20°C
AR*12/ 14/ 18/ 22LUAD
Red Pink
Pink Violet
Violet Blue
Red Black
White Red
Read Wire
367
8%
145
8%
160
8%
62.6
8%
62.6
8%
Resistance value
at 20°C
AR*9LUAB