![Fujitsu AB*14LBAJ Service Instruction Download Page 19](http://html.mh-extra.com/html/fujitsu/ab-14lbaj/ab-14lbaj_service-instruction_118000019.webp)
1. VERTICAL LOUVER CONTROL
Each time the button is pressed, the air direction range will change as follow:
Cooling / Dry mode
Heating mode
Use the air direction adjustments within the ranges shown above.
The remote control unit's display does not change.
Direction
Only the direction of the Moving Diffuser changes: the direction of the Air Direction Flaps does not change.
The vertical airflow direction is set automatically as shown,
in accordance with the type of operation selected.
Cooling / Dry mode Horizontal flow
Heating mode
Downward flow
During AUTO mode operation, for the first minute after beginning operation,
airflow will be horizontal ; the air direction cannot be adjusted during this period.
(Function Range)
(Air Direction Range)
(Operation Range)
1-2. SWING OPERATION
01-16
5-4 Wall Mounted (AS*18/ 24L) type
When the swing signal is received from the remote controller, the vertical louver starts to swing.
The range of swing depends on the set airflow direction.
When the indoor fan is either at S-Lo or Stop mode, the swinging operation is interrupted
and the louver stops at the memorized position.
( Stop mode means Operation stop.)
1
2
1
3
1
1
4
5
4
4
3
4
5
6
(Swinging Range)
Airflow direction set
Range of swing
to
to
to
to
4
1
6
6
to
to