– 143 –
2. REMOTE CONTROL UNIT CODE
SWITCHING
A B C D
A
B
C
D
Remote control unit
signal selector switch
Remote control unit
ACL button
Indoor unit
Printed circuit board
JM1
JM2
JM3
AUTORESTART
REMOCON 2
REMOCON 1
Confirm the remote control unit signal selector switch
selection and the printed circuit board setting.
If these are not set to the same setting, the remote con-
trol unit cannot be used to operate for the air condition-
er.
After setting the remote control unit signal selector
switch, press the ACL button.
Table 6
Jumper wire
Remote control unit
signal selector switch
JM 2
JM 3
Connect
Connect
Connect
Disconnect
Disconnect
Connect
Disconnect
Disconnect
A (Primary setting)
B
C
D
Fig. 44