– 132 –
Name and Shape
Q’ty
Use
STANDARD ACCESSORIES
The following installation accessories are supplied.
Use them as required.
INDOOR UNIT ACCESSORIES
OUTDOOR UNIT ACCESSORIES
ELECTRICAL REQUIREMENT
●
Always use H07RN-F or equivalent as the connection
cord.
●
Install the disconnect device with a contact gap of at
least 3 mm nearby the units. (Both indoor unit and
outdoor unit)
●
Electric wire size and fuse capacity:
1. INDOOR UNIT INSTALLATION
INSTALLATION PROCEDURE
The piping can be connected in the five directions indi-
cated by
q
,
w
,
e
,
r
, and
t
in Fig. 4. When the piping
is connected in direction
w
or
t
, cut along the piping
groove in the side of the under cover with a hacksaw.
When connecting the piping in direction
e
, cut a notch
in the thin wall at the front bottom of the under cover.
1
1
4
12
2
1
Wall hook bracket
Remote
control
unit
Battery (penlight)
Tapping screw (big)
(ø4 x 20)
Tapping screw (small)
(ø3 x 12)
Remote
control
unit holder
For indoor unit
installation
For remote
control unit
For wall hook
bracket installa-
tion
For remote
control unit
holder installa-
tion
Use for air condi-
tioner operation
Use as remote
control unit
holder
Hexagon wrench
Drain pipe
Flexible tube
Drain cap
1
1
1
2
For air purge
For outdoor unit
drain piping work
(Heat & Cool
model (Reverse
cycle) only)
Fig. 4
(Rear)
w
Right
outlet
e
Bottom outlet
q
Rear outlet
t
Left
outlet
r
Left rear
outlet
Connection
cord
(mm
2
)
20,000 BTU/h
class
MAX
MIN
Fuse capacity (A)
20
30
3.5
2.5
3.5
2.5
24,000 BTU/h
class
Table 1