6. OUTDOOR FAN CONTROL
( Table7 : Outdoor fan speed )
* The outdoor fan speed mentioned above depends on the compressor frequency.
(When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed. When the compressor frequency decreases, the outdoor fan speed also changes to the
lower speed.)
* After the defrost control is operated on the heating mode, the fan speed keeps at the higher speed
as table8 without relating to the compressor frequency.
01-06
( Table8 : Outdoor fan speed after the defrost )
1. Outdoor Fan Motor
2. Fan Speed
AC Motor
DC Motor
ASU9/ 12RLF,15RLS
Following table shows the type of the outdoor fan motor. The control method is different
between AC motor and DC motor.
( Table6 : Type of Motor )
ASU9RLF
900rpm
Cooling
Heating
ASU9RLF
ASU12RLF
ASU15RLS
Y
Z
Zone
860/ 780/ 760/ 470
900/ 760/ 720/ 680/ 470
950/ 850/ 750/ 680/ 550/ 450
1100/ 850/ 780/ 590/ 480
Refer to Fig.7
(rpm)
860/ 470/ 330
F
G
230
150
Y
Z
850/ 750/ 670/ 500
850/ 500/ 350
F
G
330
230
Y
Z
1050/ 1010/ 870/ 720/ 530
Dry
760/ 470
760/ 470
530
870/ 530/ 300
F
G
300/ 250
250/ 200
ASU12RLF
950rpm
ASU15RLS
1100rpm
( Fig.7 : Outside air temperature zone selection )
69.8°F (21°C)
50°F (10°C)
Outside air
temperature
Outside air
temperature
Z zone
Y zone
F zone
G zone
53.6°F (12°C)
35.6°F ( 2°C)
66.2°F (19°C)
32°F ( 0°C)
Summary of Contents for 9RLF
Page 3: ...1 DESCRIPTION OF EACH CONTROL OPERATION R410A WALL MOUNTED type INVERTER ...
Page 21: ...2 TROUBLE SHOOTING R410A WALL MOUNTED type INVERTER ...
Page 54: ...3 APPENDING DATA R410A WALL MOUNTED type INVERTER ...
Page 60: ...1116 Suenaga Takatsu ku Kawasaki 213 8502 Japan Sep 2010 Printed in Japan ...