background image

En-9

AIR CONDITIONER Wall Mounted Type

OPERATING MANUAL

3.

  Attach new or maintained air cleaning 

fi

 lter 

to the 

fi

 lter holder.

New air cleaning 

fi

 lter can be attached to either of the right holder or 

the left holder.

d

4.

  Latch 2 corners of the 

fi

 lter holder 

e

 to the air 

fi

 lter 

fi

 rmly.

e

e

5.

  Reinstall the air 

fi

 lter. (Refer to step 6 in “Cleaning the air 

fi

 lter”.)

6.

  Close the intake grille 

fi

 rmly.

(Refer to step 4 in “Cleaning the intake grille”.)

Following 2 types of air cleaning 

fi

 lters are used in this product.

When you replace them, purchase dedicated air cleaning 

fi

 lters for this 

product.

APPLE-CATECHIN FILTER: UTR-FA16

 

(1 sheet)

With using static electricity, puri

fi

 es the air by removing 

fi

 ne particles 

or dust such as tobacco smoke or plant pollen.

• This 

fi

 lter is disposable. Do not wash or reuse it.

•  Once you open the package, use it as soon as possible. The 

cleaning effect is reduced if the 

fi

 lter is left the package opened.

• Replace the 

fi

 lter once every 3 months under normal use.

• With setting the fan speed high, the air cleaning effect increases.

ION DEODORIZATION FILTER (light blue): UTR-FA16-2

 

(Light blue, 1 sheet)

Contained super micro-ceramic particles produce negative air ions, 
that is considered to have deodorizing effect, absorb and reduce 
room smell.

• To maintain the deodorizing effect, clean the 

fi

 lter once every 3 

months as follows:

1.

  Remove the ion deodorization 

fi

 lter.

2.

   Flush the 

fi

 lter with high-pressure hot water until the surface of 

the 

fi

 lter is covered with water.

3.

   Wash the 

fi

 lter gently with diluted neutral detergent. Do not wash 

it by wringing or rubbing to prevent reducing the deodorizing 
effect by damage.

4.

  Rinse the 

fi

 lter well with water 

fl

 ow.

5.

  Dry the 

fi

 lter thoroughly in shaded place.

6.

  Reinstall the ion deodorization 

fi

 lter to the indoor unit.

• Replace the 

fi

 lter once every 3 years under normal use.

After extended non-use of the unit

If you have shut down the indoor unit for 1 month or more, perform the 
FAN operation for half a day to dry the internal parts throughly before 
you perform normal operation.

Additional inspection

After long period of use, accumulated dust inside the indoor unit may 
reduce the product performance even if you have maintained the unit 
with instructed daily care or cleaning procedures written in this manual.
In such a case, the product inspection is recommended.
For more information, consult authorized service personnel.

  Cleaning the air 

fi

 lters

Mind that you have a periodical cleaning of the air 

fi

 lters to prevent 

reducing the operation ef

fi

 ciency of the product. 

Using of clogged air 

fi

 lter with dust will lower the product performance, 

and may cause air

fl

 ow reduction or increase of operating noise. 

Clean the air 

fi

 lters once every 2 weeks under normal use.

1.

  Open the intake grille.

 (Refer 

to 

a

 of step 1 in “Cleaning the intake grille”.)

2.

  While holding the intake grille with your hand, pull up the handle 

of the 

fi

 lter in direction of the arrow and release the 2 claws 

b

.

Then pull the 

fi

 lter out with gently sliding it downward 

c

.

a

b

b

a

c

3.

  Filter holder and air cleaning 

fi

 lter are attached on the rear side 

of the air 

fi

 lter. Remove them from the air 

fi

 lter by unlatching each 

corner of the 

fi

 lter holder 

d

.

d

d

d

d

4.

  Remove dust by using a vacuum cleaner or by washing the 

fi

 lter.

When you wash the 

fi

 lter, use neutral household detergent and 

warm water.
After rinse the 

fi

 lter well, dry it throughly in a shaded place before 

you reinstall it.

5.

  Attach the air cleaning 

fi

 lter and the 

fi

 lter holder to each air 

fi

 lter.

6.

  Attach the air 

fi

 lter with aligning both side of the 

fi

 lter with the front 

panel, and push in the 

fi

 lter fully.

Note:

 

Make sure that 2 claws are 

fi

 rmly snapped to the guide holes on the 

panel.

7.

  Close the intake grille 

fi

 rmly.

(Refer to step 4 in “Cleaning the intake grille”.)

Replacing the air cleaning 

fi

 lter

1.

  Remove the air 

fi

 lter. (Refer to step 1 in “Cleaning the air 

fi

 lter”.)

2.

  Release 2 latches 

a

 of the 

fi

 lter holder, and turn over the holder in 

direction of arrow 

b

.

Remove the soiled air cleaning 

fi

 lter 

c

.

Note:

 Air 

cleaning 

fi

 lter is attached on each air 

fi

 lter.

a

a

b

c

Cleaning and Care

9320455026_OM.indb   9

9320455026_OM.indb   9

12/4/2014   5:04:54 PM

12/4/2014   5:04:54 PM

Summary of Contents for 9-12-15RLS3

Page 1: ... water containers on top of air conditioners Do not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power...

Page 2: ...r the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 8 In SWING operation power diffuser does not move 7 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow dire...

Page 3: ...essed from a distance Notes Use specified type of batteries only Do not mix different types or new and used batteries together Batteries can be used about 1 year in ordinary use If the remote control range noticeably shortens replace the batter ies and press RESET button as shown in page 4 Remote Controller Overview and Operations You can quickly start operation with the following 3 steps 1 START ...

Page 4: ...flow direction louver The Up down Swing operation range will differ by mode as follows COOL DRY or FAN mode HEAT or FAN mode 1 2 3 4 8 7 6 5 5 1 2 3 4 5 6 7 8 Notes SWING operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped In FAN mode the Up down swing operation range of 1 5 or 6 8 is decided according to the airflow direction previously set before s...

Page 5: ...P button to change the custom code between A B C D Match the code on the display to the air conditioner custom code 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 Timer Operation Remote Con...

Page 6: ...time the air conditioner will run in the order of the program number If there is a power interruption such as due to a power outage during the WEEKLY timer setting or a circuit breaker cutting out the internal timer of the air conditioning will be incorrect See page 7 Auto restart In such a case the main timer lamp will notify you of this by flashing so carry out matching of the time and date See ...

Page 7: ...ween people s body temperature is small Such as during the summer when the temperature is 88 F 30 C or higher When there is someone in the room but they do not move for a long period of time When someone is hidden behind a sofa other furniture glass or in similar situations When someone is wearing extremely thick clothing and has their back facing the sensor Situations in which the sensor will inc...

Page 8: ...the indoor unit body mind the following Do not use water hotter than 104 F 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner Wipe the unit gently by using soft cloth Cleaning the intake grille 1 Open the intake grille in direction of the arrow a While gently pressing the left and right mounting shafts of the intake grille outward b remove the intake grille in direction...

Page 9: ...AN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual In such a case the product inspection is recommended For more inform...

Page 10: ...unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 7 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUI...