background image

En-4

OPERATING MANUAL

 

4

Remote controller display

In this section, all the possible indicators are displayed for description. 
In actual operation, the display is linked with the button operation, and 
only shows the necessary indicators for each setting.

5

POWERFUL button

Activates the POWERFUL operation. 

The unit will operate at maximum power and strong air

fl

 ow to quickly 

cool down or warm up the room.

When activated, the indoor unit will emit 3 short beeps.

To turn off, press the POWERFUL button again. The indoor unit will 

then emit 2 short beeps.
POWERFUL operation is automatically turned off in the following 

situations:

• Adjusted room temperature reaches the set temperature in COOL, 

DRY, or HEAT mode.

• 20 minutes have passed after the POWERFUL operation mode has 

been set.

Even in situations above, the POWERFUL operation will not 

automatically turn off unless it has run for a certain amount of time.

Notes:

• The air

fl

 ow direction and the fan speed are controlled automatically.

• This operation cannot be performed simultaneously with ECONOMY 

operation.

• POWERFUL operation will override the OUTDOOR UNIT LOW 

NOISE, ENERGY SAVING functions. Both functions, if set, will start 

after the POWERFUL operation is turned off.

6

MIN. (MINIMUM) HEAT button

Starts MIN. HEAT operation that maintains the room temperature at 

50 °F (10 °C) so as to prevent the room temperature to drop too low.

When you press the button to start the MIN. HEAT operation, the 

indoor unit emits 2 short beeps and the ECONOMY indicator (green) 

turns on.

Notes:

• In MIN. HEAT operation mode, only vertical air

fl

 ow direction can be 

adjusted by using SET button.

• HEAT mode will not be performed if the room temperature is warm 

enough.

7

Signal transmitter

Aim at the signal receiver of the indoor unit properly.
• Signal transmit indicator   on the remote controller display shows 

that the signal from the remote controller is being transmitted.

• Operating range is approximately 22 ft (7 m).
• You will hear a beep if the transmitted signal has been sent properly. 

If there is no beep, press the button on the remote controller again.

8

FAN button

Controls the fan speed.

(AUTO)

(HIGH)

(MED)

(LOW)

(QUIET)

• When AUTO is selected, the fan speed is automatically adjusted 

according to the operation mode.

9

SWING button

Sets the automatic swing operation. Each time the SWING button is 
pressed, the operation will change.

 Up/down 

Left/right 

Up/down/left/right 

Stop swing

• The Left/right swing operation will follow the direction as shown on 

page 2 “Horizontal air

fl

 ow direction louver”

• The Up/down Swing operation range will differ by mode as follows:

COOL, DRY, or FAN 

mode

HEAT or FAN mode

1

2

3

4

8

7

6

5

5

1

2

3

4

5

6 7 8

Notes:

• SWING operation may stop temporarily when the indoor unit fan is 

rotating at very low speed or is stopped.

• In FAN mode, the Up/down swing operation range of 1 

 5 or 6 

 

8 is decided according to the air

fl

 ow direction previously set before 

starting the swing operation.

Remote Controller Overview and Operations

See page 2

0

Vertical SET button

Adjusts the vertical air

fl

 ow direction.

See page 2

A

Horizontal SET button

Adjusts the horizontal air

fl

 ow direction.

See page 6

B

WEEKLY timer button

Activates the WEEKLY timer for a maximum of 4 on or off programs 
per day, each day of the week.

See page 6

C

SLEEP timer button

Activates the SLEEP timer that helps you to fall asleep comfortably 
with gradual temperature control.

See page 5

D

ON/OFF timer button

Activates the ON/OFF timer.

E

NEXT button

Used for adjusting the timer setting.

F

BACK button

Used for adjusting the timer setting.

G

RESET button

When you press the RESET button, press it gently by using the tip of 
a ballpoint pen or other small object in correct direction as shown in 
this 

fi

 gure.

RESET

See page 3

H

CLOCK ADJUST button

Used for adjusting the clock.

I

SEND button

Used for sending the timer/clock setting.

See page 5

J

TIMER SETTING button

Used to enter the timer setting mode.

K

SELECT button

Used for adjusting the clock or timer.

L

OUTDOOR UNIT LOW NOISE button

Starts or stops OUTDOOR UNIT LOW NOISE operation that lowers 
noise generated from the outdoor unit by cutting down the rotation 
number of the compressor, and suppressing the fan speed.
Once the operation is set, the setting is preserved until you press this 
button again to stop the operation, even if the indoor unit operation is 
stopped.

 on the remote controller display shows that the unit is in 

OUTDOOR UNIT LOW NOISE mode.

Notes:

• This operation cannot be performed simultaneously with FAN, DRY 

and POWERFUL operation modes.

M

ECONOMY button

Starts or stops ECONOMY operation that saves more electricity 
than other operation modes by changing the set temperature to a 
moderate setting.
By pressing the ECONOMY button, the ECONOMY indicator on the 
indoor unit turns on.
• In COOL or DRY mode, the room temperature will be adjusted a few 

degrees higher than the set temperature. 

• In HEAT mode, the room temperature will be adjusted a few 

degrees lower than the set temperature.

Notes:

• In COOL, HEAT, or DRY mode, the maximum output of this 

operation is approximately 70 % of usual air conditioning operation.

• This operation cannot be performed during temperature monitoring 

by AUTO mode.

(continued)

9320455026_OM.indb   4

9320455026_OM.indb   4

12/4/2014   5:04:48 PM

12/4/2014   5:04:48 PM

Summary of Contents for 9-12-15RLS3

Page 1: ... water containers on top of air conditioners Do not place any other electrical products or household belongings under indoor unit or outdoor unit Dripping condensation from the unit might get them wet and may cause damage or malfunction of your property Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power...

Page 2: ...r the angle of the power diffuser moves as follows Vertical airflow direction louver Power diffuser 3 7 6 5 4 2 1 8 In SWING operation power diffuser does not move 7 Horizontal airflow direction louver Each time you press the Horizontal SET button on the remote controller the airflow direction range of the horizontal airflow direction louver will change as follows 1 2 3 4 5 Horizontal airflow dire...

Page 3: ...essed from a distance Notes Use specified type of batteries only Do not mix different types or new and used batteries together Batteries can be used about 1 year in ordinary use If the remote control range noticeably shortens replace the batter ies and press RESET button as shown in page 4 Remote Controller Overview and Operations You can quickly start operation with the following 3 steps 1 START ...

Page 4: ...flow direction louver The Up down Swing operation range will differ by mode as follows COOL DRY or FAN mode HEAT or FAN mode 1 2 3 4 8 7 6 5 5 1 2 3 4 5 6 7 8 Notes SWING operation may stop temporarily when the indoor unit fan is rotating at very low speed or is stopped In FAN mode the Up down swing operation range of 1 5 or 6 8 is decided according to the airflow direction previously set before s...

Page 5: ...P button to change the custom code between A B C D Match the code on the display to the air conditioner custom code 4 Press the MODE button again to return to the clock display The custom code will be changed If no buttons are pressed within 30 seconds after the custom code is displayed the system returns to the original clock display In this case start again from step 1 Timer Operation Remote Con...

Page 6: ...time the air conditioner will run in the order of the program number If there is a power interruption such as due to a power outage during the WEEKLY timer setting or a circuit breaker cutting out the internal timer of the air conditioning will be incorrect See page 7 Auto restart In such a case the main timer lamp will notify you of this by flashing so carry out matching of the time and date See ...

Page 7: ...ween people s body temperature is small Such as during the summer when the temperature is 88 F 30 C or higher When there is someone in the room but they do not move for a long period of time When someone is hidden behind a sofa other furniture glass or in similar situations When someone is wearing extremely thick clothing and has their back facing the sensor Situations in which the sensor will inc...

Page 8: ...the indoor unit body mind the following Do not use water hotter than 104 F 40 C Do not use scouring cleanser volatile solvents such as benzene or thinner Wipe the unit gently by using soft cloth Cleaning the intake grille 1 Open the intake grille in direction of the arrow a While gently pressing the left and right mounting shafts of the intake grille outward b remove the intake grille in direction...

Page 9: ...AN operation for half a day to dry the internal parts throughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have maintained the unit with instructed daily care or cleaning procedures written in this manual In such a case the product inspection is recommended For more inform...

Page 10: ...unit operates at very low fan speed if the room temperature rises above the set temperature In HEAT mode the indoor unit temporarily stops for maximum of 15 minutes to perform the automatic defrosting operation while the OPERATION indicator is flashing 7 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the fan speed is set to QUI...