TIMER OPERATION

To Cancel the Timer

Use  the  TIMER  MODE  button  to  select  

“CANCEL”.

The  air  conditioner  will  return  to  normal  

operation.

To Change the Timer Settings

Perform steps 

2

 and 

3

.

To Stop Air Conditioner Operation while 

the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If  you  wish  to  change  operating  conditions 

(mode,  fan  speed,  thermostat  setting,  QUIET 

mode), after making the timer setting wait until 

the  entire  display  reappears,  then  press  the 

appropriate  buttons  to  change  the  operating 

condition desired.

To Cancel the Timer

Use  the  TIMER  MODE  button  to  select  

“CANCEL”.

The  air  conditioner  will  return  to  normal  

operation.

To Change the Timer Settings

1.  Follow the instructions given in the section 

“To  Use  the  ON Timer  or  OFF Timer”  to  

select the timer setting you wish to change.

2.  Press  the TIMER  MODE  button  to  select 

either OFF   ON or OFF   ON.

To Stop Air Conditioner Operation while 

the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If  you  wish  to  change  operating  conditions 

(mode,  fan  speed,  thermostat  setting,  QUIET 

mode), after making the timer setting wait until 

the  entire  display  reappears,  then  press  the 

appropriate  buttons  to  change  the  operating 

condition desired.

To Use the ON Timer or OFF Timer

1

  Press the START/STOP button

 

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION indicator lamp (green) will light.

2

  Press  the  TIMER  MODE  button  to  select  the  OFF 

timer or ON timer operation.

 

Each time the button is pressed the timer function changes in the following 

order:

 

       CANCEL  

OFF  

ON

 

PROGRAM (OFF 

 ON, OFF ← ON)

 

The indoor unit’s TIMER indicator lamp (orange) will light.

3

  Use  the  TIMER  SET  buttons  to  adjust  the  desired 

OFF time or ON time.

 

Set the time while the time display is flashing (the flashing will continue for 

about 5 seconds).

 button: 

Press to advance the time.

 button: 

Press to reverse the time.

About 5 seconds later, the entire display will reappear.

To Use the Program Timer

1

  Press the START/STOP button

 

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION indicator lamp (green) will light.

2

  Set the desired times for OFF Timer and ON Timer.

 

See the section “To Use the ON Timer or OFF Timer” to set the desired 

mode and times.

 

About 3 seconds later, the entire display will reappear.

 

The indoor unit’s TIMER indicator lamp (orange) will light.

3

  Press the TIMER MODE button to select the PRO-

GRAM timer operation (OFF   ON or OFF   ON will 

display).

 

The display will alternately show “OFF timer” and “ON timer”, then change 

to show the time setting for the operation to occur first.

  The program timer will begin operation. (If the ON timer has been se-

lected to operate first, the unit will stop operating at this point.)

 

About 5 seconds later, the entire display will reappear.

About the Program timer

  The program timer allows you to integrate OFF timer and ON timer operations in 

a single sequence. The sequence can involve 1 transition from OFF timer to ON 

timer, or from ON timer to OFF timer, within a 24 hour period.

  The  first  timer  function  to  operate  will  be  the  1  set  nearest  to  the  current  time.  

The order of operation is indicated by the arrow in the remote controller display  

(OFF 

 ON or OFF ← ON).

  An example of Program timer use might be to have the air conditioner automati-

cally stop (OFF timer) after you go to sleep, then start (ON timer) automatically in 

the morning before you arise.

Before using the timer function, be sure that the remote controller is set to the correct current time (

 Page 6).

If the indoor unit is connected to a wired remote controller, the wireiess remote controller cannot be used to set the timer.

s

s

s

s

9374379590-02_OM_en.indb   9

22/2/2556   17:02:51

Summary of Contents for 45

Page 1: ...AIR CONDITIONER English PART NO 9374379590 02 OPERATING MANUAL Ceiling Suspension Type Keep this manual for future reference FUJITSU GENERAL LIMITED 9374379590 02_OM_en indb 1 22 2 2556 17 02 49 ...

Page 2: ...ended periods Always turn off the electrical breaker whenever cleaning the air conditioner or changing the air filter Connection valves become hot during Heating handle with care When restarting after a long period of disuse in the winter turn the power switch on at least 12 hours before starting the unit Check the condition of the installation stand for damage Do not place animals or plants in th...

Page 3: ... under cooling mode and lower than set temp under heating mode Therefore the ECONOMY mode is able to save more energy than other normal mode OMNI DIRECTIONAL AIR FLOW SWING OPERATION 3 dimensional control over air direction swing is possible through dual use of both an up down air direction swing and right left air direction swing Since up down air direction flaps operate automatically according t...

Page 4: ...HEAT operation controlled by wire less remote controller 7 Intake grille 8 Up down air direction flaps 9 Right left air direction louvers behind up down air direction flaps 3 2 1 9 8 7 4 5 6 FEATURES AND FUNCTIONS Indoor unit n Remote controller WIRELESS REMOTE CONTROLLER The wireless remote controller allows convenient control of air conditioner operation WIRED REMOTE CONTROLLER OPTION The option...

Page 5: ...mer mode indicator N Clock indicator Some indoor units may not be equipped with the func tions corresponding to all of the buttons on this remote controller The indoor unit will beep and the OPERA TION TIMER and ECONOMY lamp flash when a remote controller button is pressed if the function is not avail able Remote controller Display NAME OF PARTS This button is used when installing the conditioner ...

Page 6: ...the direction of the arrow while pressing the mark Batteries are not included with this product 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current Time 1 Press the CLOCK ADJUST button Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons to adjust the clock to the current time butt...

Page 7: ...essed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About 3 seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat setting the ...

Page 8: ...ges the indoor unit will once again select the appropriate operation cooling to adjust the temperature to the value set in the temperature setting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN Mode operation During heating mode Set the thermostat to a temperature set ting that is higher than the current room temperature The heatin...

Page 9: ...et the time while the time display is flashing the flashing will continue for about 5 seconds button Press to advance the time button Press to reverse the time About 5 seconds later the entire display will reappear To Use the Program Timer 1 Press the START STOP button if the unit is already operating proceed to step 2 The indoor unit s OPERATION indicator lamp green will light 2 Set the desired t...

Page 10: ...C 2 C 2 C 3 C 4 C 30 minutes 1 C 1 hour 1 hour 30 minutes Set time During cooling dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting D...

Page 11: ...e up down left and right air directions with the SET buttons on the remote controller Use the SET buttons after the indoor unit has started operating and the airflow direction louvers have stopped moving Vertical Air Direction Adjustment Press the SET button Vertical Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 Types of Airflow Direction Setting 1 2 3 Du...

Page 12: ... conditioner operation before performing this procedure To Use the ECONOMY Operation Press the ECONOMY button The ECONOMY indicator lamp green will light ECONOMY operation begins To Stop the ECONOMY Operation Press the ECONOMY button again The ECONOMY indicator lamp green will go out Normal operation begins About ECONOMY Operation At the maximum output ECONOMY operation is approximately 70 of norm...

Page 13: ...r signal code is set to A prior to shipment Contact your retailer to change the signal code The remote controller resets to signal code A when the batteries in the remote controller are replaced If you use a signal code other than signal code A reset the signal code after replacing the batteries If you do not know the air conditioner signal code setting try each of the signal codes until you find ...

Page 14: ...installer or an accredited technical assistance When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel It is recommended for the user consumer to demand a copy of the Work Order every time there is a visit of a te...

Page 15: ...rosting operation 17 Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are emitted During cooling or dry operation a thin mist may be seen emit ted from the indoor unit This results from the sudden cooling of room air by the air emitted from the air conditioner result ing ...

Page 16: ...t to enter Close the curtains In the case of cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the unit set for QUIET operation The unit operates differ ently from the remote con troller setting Are the remote controller batteries dead Are the remote controller batteries loaded properly 6 TROUBLESHOOTING If the problem persists ...

Page 17: ...only to HEAT COOL MODEL Reverse Cycle Should the power supply to the air conditioner be inter rupted by a power failure the air conditioner will restart automatically in the previously selected mode once the power is restored Should a power failure occur during TIMER operation the timer will be reset and the unit will begin or stop operat ing under the new timer setting In this event the TIMER ind...

Page 18: ...9374379590 02_OM_en indb 18 22 2 2556 17 02 53 ...

Reviews: