2.Precautions for Use
① Do not drop screwdriver unit and control unit or hit them against other substances.
② Keep the screwdriver free form water and oil.
③ Do not operate screwdriver select switch while screwdriver is working.
④ Never short-circuit screwdriver output terminal.
⑤ Be sure to perform daily inspection and maintenance. If any trouble should occur, please repair the unit
as soon as possible.
⑥ No modification is allowed.To ensure safe use, never provide screwdriver unit and controller with any
modification.
3.Preparation before Use
■How to install
① Installation requirements
Do not install the unit near Heating element.
Do not subject it to direct sunrays.
② Fixing screwdriver unit
Fixing screwdriver unit to screwdriver holder
using screwdriver grip.
※Use split type screwdriver holder.
■How to connect
① Check that power switch on controller is OFF.
② Plug power cord on the back of controller into AC100V power supply outlet.
③ Plug screwdriver cord into metal outlet (2P) on the back of controller.
【Caution】Be sure to use exclusive controller.
※DO-1390A,DO-1390A-2 : 2P metal outlet (For MO-1330・1350)
④ Connect input signal (start signal ) to input/output terminal (metal outlet ,5P )
on the back of controller. Input signal must be no-voltage contact signal.
【Caution】If several-units are used at a time each input signal must be provided through respective contact.
⑤ Complete signal can be obtained through input/output terminal.
Load capacity for complate signal must be kept below AC100V 0.1A.
⑥Input/output signal connection diagram
Start Signal・・・ Input signal terminal (1-5)
Output signal terminal (2-3)
(Relay A contact)
Input signal terminal (2-4)
(Relay B contact)
Metal outlet (5P)
Panel side : PLT-165-R
Harness side : PLT-165-P
Complete
Signal
Please tighten one-page
driver's center of the gripper
with 5
~
8 N.m
Holder
Metal
outlet
Start signal
extermal
Complete
B contact
Complete
A contact
-5-