2. INSTALLATION
2.1 Electrical connection
Ensure that the voltage corresponds to that indicated in the plaque located on the oven door frame.
The cables for the connection to the mains must be protected from direct contact with the oven’s metal casing.
The plaque must never be removed.
Attention: the ground connection must be compliant with law.
After installation, carry out a brief oven check, following the instructions reported further down.
In case the appliance does not function, disconnect it from the mains and contact the after-sales assistance centre nearest to you.
Do not attempt to repair the appliance.
ATTENTION:
The manufacturer declines every responsibility for damages suffered by persons and things, caused by the non
compliance of the above prescriptions or deriving from the tampering of even a single part of the appliance and the
use of non original spare parts.
INSTRUCTIONS FOR THE INSTALLER
2.2 Oven positioning
The oven is pre-arranged for built-in purposes.
The sizes must respect the quota indicated in figures 1and 2.
The upper/rear part of the cabinet must have an opening of at least 80-90 mm deep, as indicated in figure 1.
Tighten the 4 screws by firstly inserting them inside the bush and then inside the frame (figures 1 Ref. A, B).
For installations underneath the “top” surface, ensure that the rear/lower part of the cabinet has an opening similar to that shown in figure 2.
(reference C).
Do not use the door as a lever to insert the oven inside the cabinet.
Do not put pressure on the open door.
Ovens are supplied with a three-core power cable with free terminals. And the terminals must connect with the fixed
Avoid using reductions or adaptors as they may cause overheating or burning.
wiring. If the oven is permanently connected to the power supply, install a device thet ensures disconnection
from the power supply, with a contact opening distance (at least 3mm) enabling complete disconnection in
category III overvoltage conditions. Make sure :
a) The electrical installation has sufficient voltage
b) 3x1.5 mm2 H05RR-F type cable is used when repalcing the power cable
c) The connection polarities of the free terminals are respected (Brown Line, Blue Neutral, Yellow Green Earth)
d) The fuse in your sut-up must be 16 Amperes
N.B. Make sure the characteristics of the household electrical system (voltage,maximum power and current)