Summary of Contents for FinePix S3Pro

Page 1: ...CA EU EG GE AS JP Model WARNING z THE COMPONENTS IDENTIFIED WITH THE MARK ON THE SCHEMATIC DIAGRAM AND IN THE PARTS LIST ARE CRITICAL FOR SAFETY PLEASE REPLACE ONLY WITH THE COMPONENTS SPECIFIED ON THE SCHEMATIC DIAGRAM AND IN THE PARTS LIST z IF YOU USE PARTS NOT SPECIFIED IT MAY RESULT IN A FIRE AND AN ELECTRICAL SHOCK ...

Page 2: ...ire board surface for solder splasher and bridges 2 Check the interboard wiring to ensure that no wires are pinched or contact high wattage resistors 3 Look for unauthorized replacement parts particularly transistors that were installed during a previous repair Point them out to the customer and recommend their replacement 4 Look for parts which though functioning show obvious signs of deteriorati...

Page 3: ...3 3 The camera does not automatically switch to vertical position when auto rotate function is set to ON 7 3 4 The camera does not automatically switch to vertical position when auto rotate function is set to ON 7 3 5 Image files are not read in from Microdrives 8 3 6 Media cannot be ejected 8 3 7 Images cannot be recorded 8 3 8 Recorded images are completely black 9 3 9 Noise distortion appears i...

Page 4: ...mera does not turn off Analysis results 1 LSI defect in the IEEE 1394 interface in the MAIN PWB ASSY 2 D600 F601 F603 or IC600 in the MAIN PWB ASSY is broken Replacing the faulty component remedies the problem Presumed to be caused by an overvoltage applied from the UNREG line AC adapter 3 Replacing IC112 FROM on the MAIN PWB ASSY remedies the problem An interruption to the power supply during dow...

Page 5: ... the gear teeth surfaces in the AF board assembly The balls were impeding gear rotation and preventing the rotation of the AF coupling spindle that drives the lens Repair details Replace the CAMERA BODY 2 2 The lens cannot be mounted and images become dark Fault details The lens cannot be mounted and images become dark Analysis results The aperture lever inside the mount could no longer be moved b...

Page 6: ... normal position because the shutter blade is bent Repair details Replace the CAMERA BODY 2 4 AF does not focus Fault details With the S1 the lens length ring moves but does not focus the image at all Analysis results Replacing the CAMERA BODY restored normal camera operation Results of CAMERA BODY analysis Caused by sub mirror blade 233 being disengaged from sub mirror pin 234 Repair details Repl...

Page 7: ...mera does not automatically switch to vertical position when auto rotate function is set to ON Fault details The camera does not automatically switch to vertical position when auto rotate function is set to ON Analysis results Defect in MAIN PWB ASSY IC120 vertical position detection sensor Repair details See Bulletin GS 2005 025 3 4 The camera does not automatically switch to vertical position wh...

Page 8: ... be ejected Fault details Media cannot be ejected Analysis results CN801 50 pin on the MAIN PWB ASSY was pushed in during card insertion dislodging the ejector so that the lever became disconnected and the media could not be ejected Repair details Replace the CN801 3 7 Images cannot be recorded Fault details Images sometimes appear completely black Analysis results Shutter curtain operation error ...

Page 9: ...e camera takes pictures normally but the recorded images are completely black Live images are shown vertically Repair details Replace the CCD UNIT 3 9 Noise distortion appears in recorded images Fault details Noise distortion appears in recorded images Analysis results Replacing the CCD restored normal camera operation Repair details Replace the CCD ...

Page 10: ... does not work Fault details Remote release does not work Analysis results The remote release plug was rotated forcibly while plugged into the camera turning both the plug and the plug locking screw and breaking off the terminals Repair details Replace the remote release ...

Page 11: ...display panel was bent upwards Repair details Replace the LCD 5 2 Dead pixels in the LCD Fault details Dead pixels in the LCD Analysis results Defect in the LCD monitor pixel elements Repair details Replace the LCD 5 3 LCD monitor cracked Fault details LCD monitor cracked Analysis results Damaged due to external pressure Repair details Replace the Monitor Window and LCD ...

Page 12: ... defect in connector CN400 Repair details See Bulletin GS 2005 038 6 2 IEEE 1394 communication fails Fault details IEEE 1394 communication fails Analysis results Because the cable was connected to the IEEE 1394 connector in the wrong direction the connector became loose and communication errors occurred Repair details Replace the MAIN PWB ASSY ...

Page 13: ...FUJI PHOTO FILM CO LTD 26 30 Nishiazabu 2 chome Minato ku Tokyo 106 8620 Japan ...