NOTES:
• The air conditioner custom code is set to prior to shipment.
• The remote controller resets to custom code when the batteries on the remote controller are
replaced. If you use a custom code other than code , reset the custom code after replacing
the batteries.
• If you do not know the air conditioner custom code setting, try each of the custom codes ( →
→ → ) until you find the code that operates the air conditioner.
STEP 2: Selecting the function number and setting value
1. Press the TEMP. ( ) ( ) buttons to select the function number.
To switch between the left and right digits, press the 10 °C HEAT
button.
2. Press the POWERFUL button to proceed the setting value. To re-
turn the function number selection, press the POWERFUL button
again.
3. Press the TEMP. ( ) ( ) buttons to select the setting value. To
switch between the left and right digits, press the 10 °C HEAT but-
ton.
4. Press the MODE button, and START/STOP button, in the order
listed to confirm the settings.
5. Press the RESET button to cancel the function setting mode.
6. After completing the function setting, be sure to disconnect the
power supply and then reconnect it.
Function number
Setting value
CAUTION
After disconnecting the power supply, wait 30 seconds or more before reconnecting it. The func-
tion setting will not become active unless the power supply is disconnected and then reconnect-
ed.