![Fuji Electric Frenic-Sce Instruction Manual Download Page 39](http://html1.mh-extra.com/html/fuji-electric/frenic-sce/frenic-sce_instruction-manual_2341867039.webp)
5-3
Code
Keypad code
Name
Data setting range
Factory
default
Setting
U132
U132
PID gains switching (P gain 1 for fast
reaction, Feedback < Set point)
0.00 to 30.00 times
0.00
1.4
(Note 1)
U133
U133
PID gains switching (I Integral time 1 for
fast reaction, Feedback < Set point)
0.0 to 3600.0 s
0.00
0.3
(Note 1)
y20
y20
RS-485 Communication 2 (Protocol
selection)
0: Modbus RTU protocol
1: FRENIC Loader protocol (SX protocol)
2: Fuji general-purpose inverter protocol
0
App.
(Note 1)
U128
U128
Tank level detection function (High level) 0.00 to 100.0%
100%: Maximum detection level
0.00
100.0
UA14
U15
Tank level detection function (High level
hysteresis width)
0.00 to 100.0%
100%: Maximum detection level
5
5
UA18
U19
Tank level detection function (Signal ON
Delay Time)
0.00 to 60 s
15
15
UA23
U24
Tank level detection function (Signal
OFF Delay Time)
0.00 to 60 s
15
15
U130
U130
Low power detection function (Low
Power level)
0.00 to 100.0%
100%: Motor rated power (P02)
0.00
App.
(Note 1)
UA48
U49
Low power detection function (Signal ON
Delay Time)
0.00 to 60 s
15
15
UA53
U54
Dry pump detection function (Output
frequency level)
0.00 to 100.0%
100%: Maximum frequency (F03)
80
80
UA54
U55
Dry pump detection function (Output
frequency hysteresis width)
0.00 to 100.0%
100%: Maximum frequency (F03)
5
5
UA68
U69
Dry pump detection function (Motor
power level)
0.00 to 100.0%
100%: Motor rated power (P02)
30
30
UA69
U70
Dry pump detection function (Motor
power hysteresis width)
0.00 to 100.0%
100%: Motor rated power (P02)
5
5
UA73
U194 (U190=15)
Dry pump detection function (Signal ON
Delay Time)
0.00 to 60 s
15
15
U124
U124
Dry pump detection function (Enable Dry
Pump Alarm)
0.00: Disable dry pump alarm (OH2)
1.00: Enable dry pump alarm (OH2)
0.00
0.00
U126
U126
PV panel specifications (PV panel open
circuit voltage)
0.00 to 1000 V
0.00
App.
(Note 1)
U127
U127
PV panel specifications (PV panel MPP
voltage)
0.00 to 1000 V
0.00
App.
(Note 1)
U172
U172
Measurement at open circuit voltage
condition (affected by multiplication
factor U127/U126)
0.00 to 100.0%
100%=500V (-2/-7), 1000V (-4)
-
-
U121
U121
MPP search (Enable MPP search)
0.00: Disable MPP search
1.00: Enable MPP search
0.00
1.00
U123
U123
MPP search (Enable manual setting of
PV panel voltage set point)
0.00: Disable manual setting of U171
1.00: Enable manual setting of U171
0.00
0.00
U171
U171
MPP search (Actual PV panel voltage
set point)
0.00 to 100.0%
100%=500V (-2/-7), 1000V (-4)
0.00
App.
(Note 1)
U135
U135
MPP search (Voltage/PID set point
increase/decrease step for MPP search)
0.00 to 100.0%
100%=500V (-2/-7), 1000V (-4)
0.00
0.20
UB88
U194 (U190=38)
MPP search (Time interval)
0.01 to 1.00
0.02
0.02
J15
J15
Sleep function (Sleep frequency)
0.0 (Disable): 1.0 to 500.0 Hz
0.0
App.
(Note 1)
U134
U134
Sleep function (Power level to keep
Running)
0.00 to 100.0%
100%: Motor rated power (P02)
0.00
25.0
UD88
U194 (U190=78)
Sleep function (Sleep time)
0.00 to 60 s (recommended range)
40
40
U131
U131
Wake up function (DC link voltage level
to start)
0.00 to 500 V: (200V class)
0.00 to 1000 V: (400V class)
0.00
250
500
UD98
U194 (U190=80)
Wake up function (time)
0.00 to 180 s (recommended range)
60
60
U125
U125
Big step detection (Disable)
0.00: Enable big step
1.00: Disable big step
0.00
0.00
UI08
U194 (U190=162) Big step detection (Dead time for next
action)
0.00 to 20.0 s (recommended range)
6.00
6.00
UH18
U194 (U190=144) Big step UP detection (Level to detect
big step UP)
0.00 to 100.0%
100%=500V (-2/-7), 1000V (-4)
3
3
UH48
U194 (U190=150) Big step UP detection (Time to follow the
step UP change)
0.00 to 4.0 s (recommended range)
1.0
1.0
Summary of Contents for Frenic-Sce