3.2 Overview of Operation Modes
C
hap.
3
O
P
E
R
AT
IO
N
U
S
IN
G
"T
P
-A1
-LM
2"
3.2 Overview of Operation Modes
The keypad has the following three operation modes:
Running mode
: After powered ON, the inverter automatically enters this mode.
This mode allows you to specify the reference speed, and run/stop the motor
with the / / keys during local mode.
It is also possible to monitor the running status in real time.
Programming mode : This mode allows you to configure function code data and check a variety of
information relating to the inverter status and maintenance.
Alarm mode
: If an alarm condition arises, the inverter automatically enters Alarm mode. In
this mode, you can view the corresponding alarm code* and its related
information on the LCD monitor.
*
Alarm code: Indicates the cause of the alarm condition.
Figure 3.3 shows the status transition of the inverter between these three operation modes. If the
inverter is turned ON, it automatically enters Running mode, making it possible to start or stop the
motor.
Figure 3.3 Screens Transition between each operation Modes
Programming mode
PRG
S.Spd
1450
r/min
Quick Setup
Start-up
Function Code
INV Info
Alarm Info
User Config
0.
1.
2.
3.
4.
5.
REM
PRG Menu
PRG
RESET
?
1450
STOP
Iout
r/
min
0.00
A
PWR
0.03
kW
REM
PRG
ProgramMenu
?
Set. Speed
Running mode
Alarm mode
OC1
REM
PRG
ProgramMenu
?
Latest Alarm
Over Current
During ACC
or
Release of
an alarm
Occurrence of
an alarm
( )
Power ON
(This transition by key is
ignored during occurring an alarm.)
Run/Stop motor
Monitoring running status
Setting function codes
Monitoring various statuses
Display alarm status
3-5