background image

MT6M14904b

2. Related types

© Fuji Electric Co., Ltd. All rights reserved.

Table 1 EconoPIM

TM

(PIM with built-in converter circuit and brake circuit)

The mounting instruction applies to the following module types:

650V (X series)

600 V (V series)

1200V (X series)

1200V (V series)

M711
(Type A)

25A

7MBR25VA-120-50

35A

7MBR35VA-120-50

50A

7MBR50VA-060-50

M712
(Type B)

35A

7MBR35VB-120-50

50A

7MBR50VB-120-50

75A

7MBR75VB-060-50

7MBR75VB-120-50

100A

7MBR100VB-060-50

M719
(M type)

25A

7MBR25VM-120-50

35A

7MBR35XMA120-50

7MBR35VM-120-50

50A

7MBR50XMA065-50

7MBR50XMA120-50

7MBR50VM-120-50

75A

7MBR75XMA065-50

7MBR75XME120-50

M720
(N type)

50A

7MBR50VN-120-50

75A

7MBR75XNA065-50

7MBR75XNA120-50

7MBR75VN-120-50

100A

7MBR100XNA065-50

7MBR100XNA120-50

7MBR100VN-120-50

150A

7MBR150XNA065-50

7MBR150XNE120-50

7MBR150VN-120-50

M719
(P type)

25A

7MBR25VP-120-50

35A

7MBR35XPA120-50

7MBR35VP-120-50

50A

7MBR50XPA065-50

7MBR50VP-060-50

7MBR50XPA120-50
7MBR50XPE120-50

7MBR50VP-120-50

75A

7MBR75XPA065-50

7MBR75VP-060-50

7MBR75XPE120-50

100A

7MBR100XPE065-50

7MBR100VP-060-50

M720
(R type)

50A

7MBR50VR-120-50

75A

7MBR75XRA120-50
7MBR75XRE120-50

7MBR75VR-120-50

100A

7MBR100XRA065-50

7MBR100VR-060-50

7MBR100XRA120-50
7MBR100XRE120-50

7MBR100VR-120-50

150A

7MBR150XRA065-50
7MBR150XRE065-50

7MBR150VR-060-50

7MBR150XRE120-50

7MBR150VR-120-50

EconoPIM

TM

and EconoPACK

TM

are registered trademark of Infineon Technologies AG, Germany.

3

Summary of Contents for EconoPACK M1203

Page 1: ...4904 MT6M14904b Fuji Industrial IGBT Module Solder pin type EconoPIMTM M711 M712 M719 M720 EconoPACKTM M633 M636 M668 M669 M1203 Mounting instructions Oct 2022 EconoPIMTM and EconoPACKTM are registere...

Page 2: ...k 5 3 2 Application of thermal grease 6 3 3 Screw tightening to heat sink 7 3 Mounting to heat sink 5 1 Scope of application 2 4 Mounting the module to printed circuit board 8 4 1 Soldering to printed...

Page 3: ...oPACKTM products of Fuji Electric Please refer to chapter 2 for identifiying the related module types When handling the products please follow beside the descriptions within this document additionally...

Page 4: ...50 M720 N type 50A 7MBR50VN 120 50 75A 7MBR75XNA065 50 7MBR75XNA120 50 7MBR75VN 120 50 100A 7MBR100XNA065 50 7MBR100XNA120 50 7MBR100VN 120 50 150A 7MBR150XNA065 50 7MBR150XNE120 50 7MBR150VN 120 50...

Page 5: ...100A 6MBI100XBA120 50 6MBI100VB 120 50 150A 6MBI150VB 060 50 6MBI150XBA120 50 6MBI150VB 120 50 180A 6MBI180VB 120 50 6MBI180VB 120 55 200A 6MBI200XBA120 50 6MBI200XBE120 50 6MBI250XRBE120 50 Table 2...

Page 6: ...t sink has a concave shape If both shapes exist the sum of the absolute values of the maximum and minimum values should be 50 m or less The flatness must satisfy the above value within the entire modu...

Page 7: ...e calculated from the following formula We recommend using the stencil mask method to control the appropriate thermal grease thickness Fig 2 Recommended stencil mask pattern can be provided from a rep...

Page 8: ...crewing Temporary tightening 0 5N m 1 2 3 4 Final tightening Vseries 2 5 3 5N m Xseries 2 5 6 0N m 1 2 3 4 Fig 3 Screw Tightening Torque and Screw Tightening Sequence 1 2 3 4 1 2 3 3 Screw tightening...

Page 9: ...finition of the recommended soldering temperature is terminal temperature it is different from the set temperature of the soldering machine Set the soldering unit temperature to suit the heat capacity...

Page 10: ...same order as the temporary tightening Make sure that the final tightening torque is within the range of 0 4 to 0 5 N m a Screw Tightening Torque and Screw Tightening Order for M711 M719 M636 M669 Scr...

Page 11: ...n diameter 2 4 2 6mm 2 4 2 6mm 2 4 2 6mm Product 7 0 10 0mm 4 As shown in Fig 5 use screws with a diameter of 2 4 to 2 6 mm and a length of 7 0 to 10 0 mm from the underside of the PCB 5 Manual screwi...

Page 12: ...igned for use in a dusty environment When used in an environment where dust is generated heat dissipation may deteriorate due to clogging of the heat sink and short circuits or ground faults may occur...

Page 13: ...ce with minimal temperature changes 4 During storage it is important that nothing be placed on top of the products since this may cause excessive external force on the case 5 Store products with unpro...

Page 14: ...ons characteristics data materials structure etc are as of October 2022 The contents are subject to change without prior notice due to changes in product specifications or for other reasons When using...

Reviews: