4. INSTALLATION / MOUNTING OF EQUIPMENT 

 

- Put the hood on a flat and horizontal surface to prevent it from tipping over.  
 
- In the event of an external discharge: Fix the discharge pipe in such a way as not to introduce any stresses 
that are detrimental to stability. 

- Unscrew the rear grille from the box 
- Slide the 125 mm diameter hose onto the collar 
- Secure the hose using the clamp provided 
- Take care to extend the hose to the point of external discharge, avoiding elbows as much as possible. 

 

 
- Check that the length of the power supply cable is compatible with the distance between the hood and the 
power plug. 
 
- Check that this socket has single-phase alternating grounded current wire 230 V, 50/60 Hz. It must be secured 
by a protection system guaranteeing the safety of the user. 
 
- Open the front panel and position the appropriate filter for the intended use. 
 

Installation of the activated carbon filter (identical for the particulate filter or external discharge) 

- Unscrew the knurled knob on the front face of the hood and tilt the face. 
- Install the filter (first remove the tip that may be attached to the filter frame). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for HI1P

Page 1: ...D HI HEPA Dear Customer You have just purchased a FTM Technologies product We thank you for your confidence Please read this manual carefully before using your equipment 1 Products covered by the leaf...

Page 2: ...by single phase alternating grounded current 230 V 50 hz and low voltage supply 24 VDC for the motor The body of the hood is made of polypropylene with good resistance to alkaline chemicals The operat...

Page 3: ...d be supervised to ensure that they do not play with the appliance WARNING BEFORE ANY INTERVENTION FOR EXAMPLE FILTER REPLACEMENT BE SURE TO DISCONNECT THE HOOD Avoid aspiration of liquids as well as...

Page 4: ...se using the clamp provided Take care to extend the hose to the point of external discharge avoiding elbows as much as possible Check that the length of the power supply cable is compatible with the d...

Page 5: ...grille by removing the 4 screws Insert the angled end of the silencer into the flange and make sure it is securely fastened The maintenance is done only by pressure so you have to fit everything toget...

Page 6: ...ection HI HEPA This device makes it possible to permanently know the efficiency of the filtering and to proceed to the replacement as soon as necessary In ordinary cases of use we recommend For routin...