Section 6
Parameter Settings
39
FT205EV Wind Sensors
– User Manual
6 PARAMETER SETTINGS
6.1 Command Types
6.1.1
Set Commands
Figure 30 lists the commands that may be sent to the FT205EV sensor from the host computer that are used to
SET configuration options for the wind sensor.
Command
Mnemonic
Configuration Options
Factory Default
Section
Anemometer Mount
AM
Normal
Inverted
Normal
Acoustic Temperature Units
AT
C (Celsius)
F (Fahrenheit)
K (Kelvin)
Filter Length
C (Celsius)
1 minute
Serial interface baud rate
BR
1200, 2400, 4800, 9600,
19200, 38400
9600
Compass Settings
CF
Enabled or disabled
000.0° to 359.9°
Declination angle
Disabled
0.000°
Communication Interface
CI
RS485
RS422 (always enabled)
RS422 (enabled during tx)
UART
RS485
Continuous Update
CU
Enable or Disable
Update interval, 0.1-6000
seconds
Disabled
Wind velocity data format
DF
Polar, NMEA 0183,
Combined
Polar
Command delay interval
DL
00 to 20
01
Clear Error Report
ER
Reset
000000000000
Wind velocity filter
FL
Enabled or Disabled
Speed filter length
Direction filter length
Enabled
0016
0016
Selective Filter
FL
Enable or Disable
Selective filter length
Disabled
010
Heater settings
HT
No heating functionality is provided on the
FT205 platform.
Listener and talker identifiers
ID
Listener ID = xx
Talker ID = xx
Listener ID = 01
Talker ID = WI
Min/Max wind speed
MM
Reset
999.9,000.0
Overspeed Warning Scheme
OS
Enabled or disabled
Disabled
Reset
RS
Load Current Settings,
Load Saved Parameters
NA
User Calibration Table
UC
Enable or Disable
Clear
Wind speed table record
Save wind speed table
Table label
Disabled
NA
NA
NA
6.4.23
6.4.24
6.4.25
6.4.26
6.4.27
Save User Parameters
US
Copies current
Parameters
NA
Figure 30: Set Commands
When a valid message is recognised by the sensor, the sensor will carry out the command contained in the
message. To verify that the command has been successfully carried out, an associated QUERY command can
be sent after most SET commands (see Section 6.1.2 for the list of parameters which may be queried).