Remove the shipping screws (2) completely and store in a safe place (Fig. 2).

Push down on tabletop box to release and access the connector panel. (Fig 1). The
connector panel chassis will automatically ascend from the outer assembly and expose the
connector plate openings for wiring and mounting the connector plates (not supplied). This
customer-supplied plate must not contain high voltage. This space is designed for CLASS
2 devices only.

Remove the inner box cover side screws (4) (Fig. 1) to allow access to the PTB interior for
wiring.

Cabling is inserted through the cut opening from the bottom of the table and into interior of
the table box. There is a separate compartment with a duplex outlet for 117 VAC service
entry ONLY. Be certain to isolate high and low voltage cabling per local electrical codes.
Allow enough slack in the cable runs to ensure free and full travel of the box while opening
and closing. Use tie-wraps as shown in Fig. 4 to limit strain and pinching. Open and close
the box to confirm adequate clearance.

PTB Mounting Procedure

The PTB series table thickness range is from ¾” to 4”. Adjustments are provided to
accommodate a wide range of table thickness.

Insert the PTB into the table opening and push the housing into the rabbet until the top and
surrounding rim are inside the rabbet. Adjust the four rim height adjustment screws (Fig. 2)
to 1/64” above the table surface. (Final tightening of the locking clamps will pull the table in
later steps)

FIG. 3

FIG. 4

Summary of Contents for PTB Series

Page 1: ...PDF provided by Conference Room AV FSR PTB 3 BLK Dual Sided 3 Gang Pop Up Table Box w 2 Power Black or Brass ...

Page 2: ...the property of FSR inc This publication is protected by the Federal Copyright Law with all rights reserved No part of this document may be reproduced transcribed or transmitted in any form or by any means without prior explicit written permission from FSR inc 244 Bergen Boulevard West Paterson NJ 07424 Tel 973 785 4347 Fax 973 785 4207 E Mail sales fsrinc com Web www fsrinc com ...

Page 3: ...nit is closed and not in use Solid construction and ease of installation make this durable table box a compliment to any conference room or office environment Initial Setup and Preparation The PTB is mounted from the top of the table as shown in Fig 1 A drawing Fig 6 is provided for cutting the opening and routing the rabbet on the table Consideration should be given to placement and position to e...

Page 4: ...terior of the table box There is a separate compartment with a duplex outlet for 117 VAC service entry ONLY Be certain to isolate high and low voltage cabling per local electrical codes Allow enough slack in the cable runs to ensure free and full travel of the box while opening and closing Use tie wraps as shown in Fig 4 to limit strain and pinching Open and close the box to confirm adequate clear...

Page 5: ...to secure the adjustment position After height adjustments are completed install and tighten the locking clamps 2 as shown in Fig 5 to lock the PTB into place There is a factory installed duplex outlet provided for local 117 VAC power at the PTB faceplate The 8 AC cord can be plugged into a 117 VAC outlet close to the PTB housing The PTB s power cord is the main disconnect device The power socket ...

Page 6: ...FSR PTB Installation Manual Page 5 of 6 ...

Page 7: ...allow the exclusion of incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date if a Warranty Registration Card was mailed in at the time of purchase this i...

Reviews: