8
MAS-6100 / MAS-6100A
FRONT AND REAR PANEL OPERATION
FRONT PANEL CONTROLS
POWER ON OFF
Pressing the power button will power up the MAS-6100. The unit will run a brief diagnostic sequence
and be operational in a few seconds. Pressing and holding the power button for two seconds and
releasing will power down the unit.
INPUT
SELECT
Press and release any of the six input select buttons to select and display the desired video source. An
audio switch will follow if there is an audio input associated with the new video input selected. (MAS-
6100A only). See “Audio Input Number” setting under Input Setup for details on audio input setup
selection and muting.
TRANSITION CONTROL:
FREEZE
Press and release to freeze the current display. This does not affect the background image. A second
press will unfreeze the display. This setting is also available through the on screen menu.
KEY
Press and release to enable Keying. The key color default is black and will be transparent allowing
the background image to show through. This setting can be changed to any chroma or luma settings
through the on screen menu.
LOCK
Press to activate GENLOCK. This locks the unit’s output to the current lock source. See “adjust
outputs menu” for details. This setting is also available through the on screen menu.
BGND
Press and release to put the unit into “Lock and Mix” mode. This will allow the use of the Key and
Dissolve effects. This setting is also available through the on screen menu.
NOTE:
When using YUV as a background, the YUV input must be progressive.
DISSOLVE
Fades the current image in and out. When BKND is active the unit will fade between the current and
previously selected input. If keying is active, the unit will fade in and out of key mode.