MAS 4100A Scaler/Swicher
Command/Response codes of RS-232 transmission:
The command and response codes are a combination of 3 bytes. The 1st and 2nd bytes are text and the
3rd byte is a HEX value. No carriage return is necessary.
Remote Controller Command Codes
Code
Comment
‘PW’+0
POWER
power off (standby)
‘PW’+1
power on (normal)
‘IN’+0
Composite video
‘IN’+1
INPUT
S-video
‘IN’+2
YCbCr
‘IN’+3
PC bypass
‘JA’+0
JACK
HD-15 (D-Sub)
‘JA’+1
BNC
‘OU’+0
VGA
‘OU’+1
OUTPUT
480p
‘OU’+2
SVGA
‘OU’+3
XGA
‘OU’+4
SXGA
‘OU’+5
576p
‘OU’+6
720p
‘OU’+7
1080i
‘OU’+8
UXGA
‘OU’+9
1365x768
‘DI’+0
DISPLAY
osd display OFF
‘DI’+1
osd display ON
‘BR’+value
brightness
value – 0~255
‘CO’+value
contrast
value – 0~63
‘SA’+value
saturation
value – 0~127
‘SH’+value
sharpness
value – 0~14
‘TI’+value
tint
value – -30~+30
‘RE’+0
reset
video adjustment reset
‘ZV’+value
vga vert freq
value = 0:60hz 1:72hz 2:75hz 3:85hz
‘ZS’+value
svga vert freq value = 0:60hz 1:72hz 2:75hz 3:85hz
‘ZX’+value
xga vert freq
value = 0:60hz 1:70hz 2:75hz
‘IR’+0
IR
IR sensor OFF
‘IR’+1
IR sensor ON
‘FP’+0
PANEL
front panel lockout ON
‘FP’+1
front panel lockout OFF
Summary of Contents for MAS 4100A