background image

 

8

Mode Switch Label 

 

 

 

 

Single Relay Interlock Mode (SPDT) 

   Mode 

Switch 

Setting 

000 

 

This mode provides the ability to control each of the four SPDT relays through switch inputs A through D. 
When one relay is activated or turned on, the other relays are turned off.  For example if the user turns on Relay 
#1 using switch input “A”, then Relays 2, 3 and 4 are turned off. Switch input E turns off all Relays.

  

 
Multiple Relay Activation – Alternate Action   

 

 

Mode Switch Setting 001 

 

This mode toggles each individual Relay on or off. The first switch closure turns the relay on and the second 
switch closure turns the relay off. Any combination of switches may be activated at the same time. Switch input 
E, when activated, overrides all other switch inputs and turns off all relays. 
 

Multiple Relay Activation – Momentary ON 

  

 

Mode Switch Setting 010 

 

This mode turns on the corresponding relay for the duration of the switch closure. Switch E turns on all relays 
for the duration of the closure. Any number of relays can be operated at the same time. 
 

Dual Relay Mode (DPDT) - Push On/Push Off    

 

 

Mode Switch Setting 011 

 

 

This mode provides the ability to pair up the Relays for use in a Dual Relay application. Each pair R1/R2 and 
R3/R4 effectively become DPDT relays when configured in this mode. Switch A turns on relays 1 & 2; Switch 
B turns off relays 1 & 2.  Switch C turns on relays 3 & 4, and switch D turns off relays 3 & 4. Switch E turns 
off all relays. 

 
Dual Relay Modes   (DPDT)  - Alternate Action    

 

Mode Switch Setting 100 

 

This mode provides the ability to toggle each pair of Relays. Switch “A”, toggles relay pair R1/R2 and Switch 
C toggles relay pair R3/R4.  Switch D unconditionally turns on both pairs of relays and switch E 
unconditionally turns off both pairs.  
 

Dual Relay Modes   (DPDT) Alternate Pulsed 0.25 sec   

 

Mode Switch Setting 101 

 

This mode provides the ability to pulse each relay for a given application that may require the use of a trigger 
pulse for turning on some type equipment.  

 

Switch A the first press sends a ¼ second pulse to relay 1; the second press sends a ¼ second pulse to 
relay 2. 

1=

0=

Summary of Contents for INTELLI-TOOLS IT- R4

Page 1: ...Operating Guide INTELLI TOOLS IT R4 Switch or Logic Level Controlled Relay Module 244 Bergen Blvd West Paterson NJ 07424 1 800 332 FSR1 http www fsrinc com 43924 LIT1222C ...

Page 2: ... incidental or consequential damages so the above limitations may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state Warranty claims should be accompanied by a copy of the original purchase invoice showing the purchase date if a Warranty Registration Card was mailed in at the time of purchase this is not necessary Before...

Page 3: ...8 Multiple Relay Activation Alternate Action Mode Switch Setting 001 8 Multiple Relay Activation Momentary ON Mode Switch Setting 010 8 Dual Relay Mode DPDT Push On Push Off Mode Switch Setting 011 8 Dual Relay Modes DPDT Alternate Action Mode Switch Setting 100 8 Dual Relay Modes DPDT Alternate Pulsed 0 25 sec Mode Switch Setting 101 8 Quad Relay Mode Mode Switch Setting 101 9 Special Function Mo...

Page 4: ...cal P O C P O C 3 4 RELAY RELAY 2 1 A INPUTS CONTROL B E D POWER 12VDC 0 2A NTELLI OOLS IT R4 MODEL C MODE SWITCH SEE BOTTOM FOR DETAILS 1 1 2 3 4 ON 1 OFF 0 P O C P O C 3 81 3 00 4 25 3 44 22 22 22 22 4x 203 DIA 1 57 ...

Page 5: ... Each relay can be set for different operating modes On Off pulsed for a of a second or toggled which changes the relay to the opposite state For a detailed description of operation and settings see the Switch Input Actuation Table Features One module does the work of many Quick easy setup and configuration Small footprint High quality relays Quick connect terminals Integral mounting plate Applica...

Page 6: ...ONTROLLED DEVICE TO AC POWER AC ADAPTER SOLD SEPARATELY MODEL IT PS1 FSR PN 16805 Caution The IT R4 and IT R4S relay interface modules are not intended to directly switch AC line voltages Connection to lighting and shade and screen systems should be done at the low voltage control interface provided by the manufacturer If you must interface to AC line voltages add a relay module designed for this ...

Page 7: ...ted on the main PCB Switches S1 through S3 are used for accomplishing this while the fourth position is used to control the logic state at which the relays will operate S4 closed allows active low inputs to turn on the relay while S4 open allows active high inputs to turn on the relay Switch Input Actuation Table Switch Inputs A E Switch Possibilities 1 Gnd 0 V to operate 2 24V 24V Max 2V Min Or 1...

Page 8: ... relays for the duration of the closure Any number of relays can be operated at the same time Dual Relay Mode DPDT Push On Push Off Mode Switch Setting 011 This mode provides the ability to pair up the Relays for use in a Dual Relay application Each pair R1 R2 and R3 R4 effectively become DPDT relays when configured in this mode Switch A turns on relays 1 2 Switch B turns off relays 1 2 Switch C t...

Page 9: ...unctions Special Function Mode Mode Switch Setting 111 Switch A turns relays 1 2 on and sends second pulse to relay 3 Switch B turns relays 1 2 off and sends second pulse to relay 4 Switch C first press turns on relays 1 2 and pulses relay 3 for second The second press turns off 1 2 and pulses relay 4 for second Switch D the leading edge performs Switch A function trailing edge performs Switch B f...

Page 10: ...10 ...

Page 11: ... range 2 0 24V Input Voltage Logic Low range 1 0 1 0V Input Impedance 7k Minimum Actuation Time to recognize a valid switch input 0 1 Sec Power Power supply 12 VDC 160mA fully loaded FSR IT PS1 16805 may be ordered separately Mechanical and Environmental Connectors Screw terminals Overall dimensions see drawing for details 4 25 L x 3 44 W x 1 57 H Shipping weight 0 9 lbs Ambient temperature 0 to 5...