FLEX-IO ACTION COMMANDS
GPI
Queries or sets the specified General Purpose Input.
GPI number_or_number_sequence state_or_query
number_or_number_sequence
each channel has to be in the range of 1 of to 16.
Can be a single channel. ( Example: 4 )
Can be a range of channels separated by a dash. ( Example: 1 – 8 )
Can be a series of single channels or ranges of channels separated by commas. (Example: 1 –
3, 6, 10 – 12 )
state_or_query
HIGH = pulses the HIGH setting once in software (see accompanying Table)
LOW = pulses the LOW setting once in software
E = enable
D = disable = Once a channel is Disabled, it must be Enabled before it can be set HIGH.
? = request current state for specified channel(s)
Samples:
GPI 2 HIGH
GPI 1-8 D
GPI 1, 3-8, 11-16 E
Channel Type
HIGH
LOW
“Normally Open”
Executes Actions
(nothing)
“Normally Closed”
(nothing) Executes
Actions
“Executes Actions” details:
“Normal” tab = fires “Press” and “Release” Actions. (“Hold” Actions within the IO-16 cannot be
executed programmatically.)
“Toggle” tab = fires either the “Odd” or “Even” Actions.
Summary of Contents for Flex-IO16
Page 21: ...21 Then press the Connect button to confirm the new Firmware version number appears ...
Page 23: ...23 ...
Page 24: ...24 ...
Page 28: ...28 OPEN AN EXISTING PROJECT ...
Page 29: ...29 ...
Page 31: ...31 Click the Download Project button Click the Start Download button ...
Page 32: ...32 Click the OK button ...
Page 33: ...33 Wait for the reboot of the Flex IO hardware to finish Click the Connect button ...
Page 40: ...40 ...
Page 42: ......