6 Command List:
CON
Connect input to output(s)
HAU
HDMI Audio Output command
HEDID
HDMI EDID setting
INSRC
Input Source command
SAO
Stereo Audio Output command
PRESET
Preset Recall command
RST
Reset
DV-MFSW-94
BAUD
Sets the RS232 baud rate
IPADR
Sets the IP address
STAT
Universal Status command
NOTE:
All commands are terminated with a carriage return (0Dhex) represented by <cr>
The default baud rate is 38400 bps.
6.1 Set CON Command
Tells the DV-MFSW-94 which outputs to connect to which input
CON
id
input
“(“
output
“,”
output
“,” ……”)”[“;”
input”
(“
output
,,,,”)”] <
cr
>
WHERE:
CON
3 ASCII byte command name
id
2 byte unit ID
input
An input number between 1 – 9
“(“
Parentheses indicating the start of the outputs to connect the input to.
output
an output number 0 – 4 to connect to the input, zero representing no input. Multiple outputs
can be included in the list separated by a comma.
“)”
Parentheses to end the list of outputs
“;” Delimiter separating additional definitions
<
cr
>
Carriage Return (0Dhex)
Example:
Connect Unit 01 input 1 to outputs 2, 3 and 4 and input 2 to output 1.
CON 01 1(2,3,4); 2(1)
<