background image

FSN2006 - 4/2019

English - 23

Controls

On Screen Display (OSD) Touchscreen

Touchscreen icons, located in bottom right corner of the LCD display, allows

the user to make adjustments to various display parameters using the On Screen Dis-

play (OSD) system. Slightly touch any icon to activate all of the icons.

 FM-A2701D 

  FM-A2701DS

 FM-B2702D  FM-B2702DG

To change input signal sources, press INPUT and move the 
cursor by pressing the UP or DOWN icons. Press PLUS to 
select the desired source.

For FM-A2701DS and 
FM-B2702DG, SDI source type 
can be changed by pressing  
MINUS when the cursor  is next 
to SDI in the source list. 

FM-B2702DG

FM-A2701DS

Summary of Contents for FM-A2701D

Page 1: ...Medical Display FM A2701D FM A2701DS FM B2702D FM B2702DG User s Guide Before connecting operating or adjusting this product please read this instruction booklet carefully and completely ...

Page 2: ...11 Parts 16 18 Connectors 17 19 Mechanical Drawing 20 21 Controls 22 23 Window Layout 24 25 On Screen Display OSD 26 28 Standard Signal Tables 29 Signal Connector Pin Assignments 30 32 General Specification 33 34 Cleaning Instructions 35 36 The specifications and information in this document are subject to change without notice ...

Page 3: ...nct color space settings have been calibrated to well known surgical color preferences providing the user with the ideal surgical visualization system Features include Rapid signal detection robust mode tables Artifact free 4K UHD images Fanless sterile field compatible Calibrated to clinical color Image pan zoom freeze picture in picture FSN Medical Technologies has solutions for managing your op...

Page 4: ...r Direct Current lndicates equipotential earth ground Indicates protective earth ground Indicates top bottom direction DC Power control switch Fragile Do not get wet Maximum Stacking Consult the operating instruc tions Indicates the manufacturer Indicates the manufacturing date Authorized representative in the European community Serial Number Humidity limitation Temperature limitation Atmospheric ...

Page 5: ...ly with FCC Class B standard This symbol indicates that the waste of electronic equipment must not be disposed as unsorted municipal waste and must be collected separately Please contact the manufacturer or other authorized disposal company to decommission your equipment Language English Note A printed copy of the manual in English is provided with the product Users within EU member states please ...

Page 6: ...rized dealer or service center 9 Please contact the manufacturer if the set should be installed in an inaccessible area Warning Do not touch input or output connectors and the patient simultaneously Warning This medical LCD monitor is intended for connection to input output signals and other connectors that comply with relevant IEC standard e g IEC60950 for IT equipment and IEC60601 series for med...

Page 7: ...it away from heaters stoves fireplaces and sources of heat 6 Don t place your medical LCD Monitor on an unstable stand Medical LCD monitor may mal function or fall 7 This medical LCD monitor should not topple over when tilted at a 5 angle in any position during NORMAL USE excluding transport 8 In the position specified for transport medical LCD monitor shall not overbalance when tilted at a 10 deg...

Page 8: ...aboratories UL Classification UL safety Compliance This medical LCD monitor is U L Classified WITH RESPECT TO ELECTRIC SHOCK FIRE AND ME CHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 60601 1 CAN CSA C22 2 NO 601 1 EEC Safety and EMC Compliance This medical LCD monitor unit meets the requirements of EN60601 1 and EN60601 1 2 so as to conform to the Medical Device Directive 93 42 EEC This medical LCD ...

Page 9: ...peration If such use is necessary this equipment and the other equipment should be observed to verify that they are operating normally Warning Use of accessories transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operati...

Page 10: ...the power cord or plug is damaged or frayed If liquid has been spilled into the medical LCD monitor If objects have fallen into the medical LCD monitor If the medical LCD monitor has been exposed to rain or moisture If the medical LCD monitor has been subjected to excessive shock by being dropped If the cabinet has been damaged If the medical LCD monitor seems to be overheated If the medical LCD m...

Page 11: ...ference 3 Plug the monitor into an outlet on a different electrical circuit than that to which the subject of interference is connected 4 Consult the dealer or an experienced radio TV technician for help NOTICES TO USER This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must acce...

Page 12: ...ical LCD monitor should make sure that it is used in such an environment Interference immunity test IEC 60601 1 2 2014 con formity level Electromagnetic environment guidance Electrostatic discharge ESD acc to IEC 61000 4 2 Complies 2 kV 4 kV 6 kV 8 kV contact discharge 2 kV 4 kV 8 kV 15 kV air discharge Floors should be made of wood concrete or ceramic tile If floors are covered with synthetic mat...

Page 13: ... 1 0 27 450 430 to 470 GMRS 460 FRS 460 FM 5 kHz stroke 1 kHz sine wave 2 1 0 28 710 704 to 787 Band 13 17 Pulse modulation 217 Hz 0 2 1 0 9 745 780 810 800 to 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation 18 Hz 2 1 0 28 870 930 1720 1700 to 1990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation 217 Hz 2 1 0 28 1845 1970 2450 2400 to 2570 Bluetooth ...

Page 14: ... recommended separation distance in meters m The field strength of stationary transmitters at all frequencies on site a should be according to a study less than the conformity level b d 1 2 P 80 MHz to 800 MHz d 2 3 P 800 MHz to 2 5 GHz Interference may occur in the vicinity of equipment marked with the following symbol Note These guidelines may not apply in all situations The propagation of elect...

Page 15: ... device as a function of the output power of the communication device as shown below Nominal power of transmitter W Separation distanced m according to frequency of transmitter 150kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed abov...

Page 16: ... 27 FM A2701D 16 English Parts Monitor Accessories User Manual AC DC Adaptor 6 23ft 1 9m AC Power Cord 6ft 1 8 m US UK EU China Hospital Grade DisplayPort Cable HDMI Cable SDI BNC Cable x 4 FM A2701DS Screw BH M4 x 14 DVI D Cable ...

Page 17: ...T IN USB SVC 5V OUT 2 DISPLAY PORT 2 IN GROUND SDI 4 IN OUT DC IN RS232C IN OUT SDI 3 IN OUT SDI 1 GPIO HDMI IN DVI IN DVI OUT 5V OUT 1 SDI 2 IN OUT DC ON OFF SWITCH DISPLAY PORT 1 OUT IN USB SVC 5V OUT 2 DISPLAY PORT 2 IN English 17 Connectors 27 FM A2701D Monitor Connector 27 FM A2701DS Monitor Connector ...

Page 18: ...27 FM B2702DG 18 English Parts Monitor Accessories User Manual AC DC Adaptor 6 23ft 1 9m AC Power Cord 6ft 1 8 m US UK EU China Hospital Grade DisplayPort Cable HDMI Cable SDI BNC Cable x 4 FM B2702DG Screw BH M4 x 14 DVI D Cable ...

Page 19: ...MI IN DVI IN DVI OUT 5V OUT 1 SDI 2 IN OUT DISPLAY PORT 1 OUT IN USB SVC 5V OUT 2 DISPLAY PORT 2 IN GROUND RS232C DC IN GPIO HDMI IN DVI IN DVI OUT 5V OUT 1 DISPLAY PORT 1 OUT IN USB SVC 5V OUT 2 DISPLAY PORT 2 IN English 19 Connectors 27 FM B2702D Monitor Connector 27 FM B2702DG Monitor Connector ...

Page 20: ...FSN2006 4 2019 FM A2701DS 658 8 mm 25 94 in 426 16 77 60 2 36 25 98 100 3 94 100 3 94 200 7 87 8 M4 VESA 20 English Mechanical Product Drawing 27 FM A2701D FM A2701DS Dimension ...

Page 21: ...FSN2006 4 2019 FM B2702DG 425 16 73 75 2 2 96 44 6 1 76 673 mm 26 5 in 100 3 94 8 M4 VESA 100 3 94 200 7 87 187 3 7 37 English 21 Mechanical Product Drawing 27 FM B2702D FM B2702DG Dimension ...

Page 22: ...ble PIP Pic ture in Picture function Not available when Smart Input is enabled Press to turn power on off to the display s front LCD screen If this icon is not illumi nated then the power switch on the back of the display has been turned off Press to show the input selection menu and to change the display signal source When the OSD menu is activated press to enter a sub menu or increase the adjust...

Page 23: ...e On Screen Dis play OSD system Slightly touch any icon to activate all of the icons FM A2701D FM A2701DS FM B2702D FM B2702DG To change input signal sources press INPUT and move the cursor by pressing the UP or DOWN icons Press PLUS to select the desired source For FM A2701DS and FM B2702DG SDI source type can be changed by pressing MINUS when the cursor is next to SDI in the source list FM B2702...

Page 24: ...SDI Quad SDI Source Compatibility SDI 1 or SDI 2 or SDI 3 or SDI 4 SDI 1 or SDI 2 SDI 1 SDI 2 SDI 3 SDI 4 Window 1 Window 1 Window 2 Window 2 For SDI single view setting use the INPUT menu to select which SDI source should be activated For SDI quad view setting each con nector should correspond with the four image areas as shown above 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 ...

Page 25: ...1 SST DisplayPort 2 SST HDMI DVI DisplayPort 1 SST DisplayPort 2 SST HDMI DVI FM A2701DS FM B2702DG DisplayPort 1 SST DisplayPort 2 SST HDMI SDI 1 2 3 4 quad 2 SI DVI DisplayPort 1 SST DisplayPort 2 SST HDMI SDI 1 2 3 4 quad 2 SI DVI PiP PbP Combination Table ...

Page 26: ...or To close the OSD menu press the menu button to exit from the main menu or a sub menu 2 Pick a Main Menu Category After entering the OSD use the UP and DOWN buttons on the front of the display monitor to navigate to a main menu category The PICTURE menu controls brightness contrast and more The COLOR menu controls preset or customized color settings The ADVANCED menu controls image aspect ratio ...

Page 27: ...tting BT 709 for HD signal setting BT 2020 for UHD signal setting AUTO automatically changes to BT 2020 for UHD or BT 709 for HD signal 3 COLOR MODE Changes the image color setting C1 C2 C3 USER 4 RED Red balance Only works with USER mode Range 0 100 5 GREEN Green balance Only works with USER mode Range 0 100 6 BLUE Blue balance Only works with USER mode Range 0 100 Submenus under the ADVANCED men...

Page 28: ...LE PBP PIP Submenus under the LAYOUT menu PBP 1 LAYOUT Changes the image layout SINGLE PBP PIP 2 WINDOW SELECT Selects the active window during PBP or PIP 3 INPUT SWAP Swaps the position of the primary and secondary images Submenus under the LAYOUT menu PIP 1 LAYOUT Changes the image layout SINGLE PBP PIP 2 WINDOW SELECT Selects the active window during PBP or PIP 3 INPUT SWAP Swaps the position o...

Page 29: ...00 60 00 108 00 1280 x 960 85Hz 85 94 85 00 148 50 1280 x 1024 60Hz 63 98 60 02 108 50 1280 x 1024 75Hz 79 98 75 02 135 00 1280 x 1024 85Hz 91 15 85 02 157 50 720p 50Hz 37 50 50 00 74 25 720p 59 94 44 96 59 94 74 176 720p 60Hz 45 00 60 00 74 25 1080i 50Hz 28 13 50 00 74 25 1080i 59 94Hz 33 72 59 94 74 167 1080P 50Hz 56 25 50 00 148 50 1080P 59 94Hz 67 43 59 94 148 352 1080P 60Hz 67 50 60 00 148 50...

Page 30: ...a 1 22 T M D S Clock Shield 11 T M D S Data 1 Shield 23 T M D S Clock 12 No Connection 24 T M D S Clock HDMI input interface connector Pin No Assignment Pin No Assignment 1 T M D S Data 2 11 T M D S Clock Shield 2 T M D S Data 2 Shield 12 T M D S Clock 3 T M D S Data 2 13 CEC 4 T M D S Data 1 14 Reserved 5 T M D S Data 1 Shield 15 SCL 6 T M D S Data 1 16 SDA 7 T M D S Data 0 17 Ground 8 T M D S Da...

Page 31: ...face connector if available Pin No Description 1 SDI input 2 Ground RS232C interface connector Pin No Assignment Pin No Assignment 1 No Connection 6 No Connection 2 TXD Monitor to PC 7 No Connection 3 RXD PC to Monitor 8 No Connection 4 No Connection 9 No Connection 5 Ground Important Do not use a null modem cable Use only a standard RS 232 cable USB interface connector Pin No Assignment Pin No As...

Page 32: ...monitor saves energy by switching into a low power mode when it has not been used for a certain period of time Normal operation automatically returns to the monitor when horizontal and vertical sync return Power Consumption Normal operation LED off Standby mode LED blinking OSD power off LED constant DC power off LED off FM A2701D 90W 35W 27W 0 5W FM A2701DS 110W 35W 27W 0 5W FM B2702D 85W 40W 20W...

Page 33: ... HDMI 2 0 2 x DP 1 2 SST 1 x DVI single link 4 x SDI 3G available only on FM A2701DS Output Signal 1 x DVI single link 1 x DP 1 2 SST 4 x SDI 3G available only on FM A2701DS Power Supply AC DC Adaptor AC 100 240V DC 24V 6 6A Power Consumption FM A2701D 90W max FM A2701DS 110W max Unit Dimension 658 8 W x 426 H x 60 D mm 25 94 W x 16 77 H x 2 36 D inch Package Dimension 755 65 W x 654 05 H x 234 95...

Page 34: ...I 2 0 2 x DP 1 2 SST 1 x DVI single link 4 x SDI 3G 2 x SDI 12G available on FM B2702DG Output Signal 1 x DP 1 2 SST 1 x DVI single link 4 x SDI 3G 2 x SDI 12G available on FM B2702DG Power Supply AC DC Adaptor AC 100 240V DC 24V 6 6A Power Consumption FM B2702D 85W FM B2702DG 100W Unit Dimension 673 W x 425 H x 75 2 D mm 26 50 W x 16 73 H x 2 96 D inch Package Dimension 755 65 W x 654 05 H x 234 ...

Page 35: ...ics Instead apply the liquid to the cleaning cloth Follow your hospital protocol for the handling of blood and body fluids The display is not disinfected or packed in sterile environment Follow your hospital protocol in case the display needs to be disinfected prior to installation Front Filter Proceed as follows 1 Remove dust with a dry lint free non abrasive soft cotton cloth 2 Remove fingerprin...

Page 36: ...zed cleaning prod uct for medical equipment Repeat with water only Wipe dry with a dry cloth The cabinet has been tested for resistance to the following products Virex Ready to use Disinfectant Cleaner Misty Clear Lemon 10 Disinfectant Misty Multi Purpose Disinfectant Cleaner Misty Multi Purpose Disinfectant Cleaner II Zep Heavy duty glass all surface cleaner Klear Screen Screen TFT Kontakt Chemie...

Page 37: ...FSN2006 4 2019 English 37 Notes ...

Page 38: ...FSN2006 4 2019 38 English Notes ...

Page 39: ...FSN2006 4 2019 English 39 ...

Page 40: ...eatherhead Road Chessington Surrey KT9 2NY UK Tel 44 0 208 546 1047 FORESEESON KOREA 404B Pangyoinnovalley B 253 Pangyo ro Bundang gu Seongnam si Gyeonggi do Korea 463 400 Tel 82 31 8018 0780 Fax 82 31 8018 0786 FORESEESON Shanghai Medical Equipment Co Ltd Room 307 3F No 56 461 Hongcao Road Caohejing Development District Xuhui Shanghai 200233 Tel 86 21 6113 4188 FORESEESON CUSTOM DISPLAYS INC 2210...

Reviews: