11
Programming of the Texecom Premier two COM Port Alarm Panel
Program the TXC+ to use the Texecom Serial Alarm Interface (DTMF – Serial Interface Tab)
The TXC+ is connected to COM1 on the Alarm Panel
The following programming is required on the Texecom panel:
MENU 71
0 TEL NO 22 (YES)
1 ACC CODE 3456 (YES)
2 PROTOCOL TYPE = 4 (CONTACT ID)
3 DIALLER ATTEMPTS = 1
4 PARTITION (SELECT PARTITIONS 1 AND 2)
5 SELECT REPORTING OPTIONS
MENU 70 1,2,5,8 ON (ENABLE COMMUNICATOR)
MENU 76 COM1 DEVICE TYPE – 3 (ComIP PROTOCOL)
Uploading and Downloading the Texecom Premier Alarm Panel
The Texecom premier alarm panel can be uploaded and downloaded using the Texecom WinTex
software (available at www.texe.com). Please contact the local Texecom agent for more details
A PC based modem for is available from FSK Electronics which can be used to connect to the Alarm
Panel (via the TXC+)
The Wintex Software requires the IP Address and Port Number of the TXC+ to be entered in the
Account Details section of Wintex. The IP Address of the TXC+ is provided by FSK.
If the FSK APN Connector is being used, the IP Address is always 127.0.0.1.
The Port is Always set to ‘9090’
Select the Panel Modem Type as ComISDN
IP ADDRESS OF
THE TXC+ ON THE
FSK PRIVATE APN
127.0.0.1 IF USING
APN CONNECTOR