APPENDIX B - FSK ALARM CODES
The Router 0211 is capable of receiving either FSK Alarms or Contact ID Alarms.
If the format of the alarm received is not the same as the serial port protocol selected
(see Appendix A) the Router 0211 will convert from the one format to the other.
For example, if an alarm is received in the FSK format and the RS232 format is set to FSK7
(Contact ID), the Router 0211 will convert the FSK format alarm to its Contact ID
equivalent.
If an alarm is received in Contact ID format and the RS232 protocol is set to FSK , the
Router 0211 will attempt to convert the alarm to the equivalent FSK code.
Note that not all Contact ID codes have an equivalent FSK code.
TABLE B1: FSK ALARM CODES AND EQUIVALENT CONTACT ID CONVERSION
FSK
FSK
FSK
CONTACT ID
PTY
LIMIT
CODE
DESCRIPTION
ALTERNATE
USE
CODE
E
DESCRIPTION
ZONE
ALARM
TELEM
R
0
AUTO TEST
602
E
Periodic test report Zone
0
NO
YES
1
CANCEL BY KEYH 1
406
E
Cancel User
1
NO
NO
2
TELEMETRY 2
COMMS
RESTORED
357
E
Long Range Radio
2
NO
NO
3
TELEMETRY 3
603
E
Periodic RF Test
3
NO
NO
4
POINTS MISSED
708
E
POINTS MISSED
0
NO
NO
5
PATROL START LATE
703
E
PATROL START LATE
0
NO
NO
6
PATROL START ON
TIME
702
E
PATROL START
0
NO
NO
7
GUARD PATROL SLOW
711
E
GUARD PATROL SLOW
0
NO
NO
8
GUARD PATROL FAST
712
E
GUARD PATROL FAST
0
NO
NO
9
GUARD FAIL TO START
SHIFT
716
E
GUARD FAIL TO START SHIFT
0
NO
NO
10
PROGRAM COMPLETE
628
E
Program Mode Exit
0
NO
NO
11
GUARD LATE ON DUTY
707
E
GUARD LATE ON DUTY
0
NO
NO
12
WRONG ROUTE
718
E
WRONG ROUTE
0
NO
NO
13
SUPERVISOR ON SITE
140
E
Supervisor on site
13
NO
NO
14
SUPERVISOR OFF SITE
140
R
Supervisor on site
14
NO
NO
15
OPEN KEYH 99
409
E
Keyswitch O/C
99
NO
NO
16
ELECTRIC FENCE
131
E
Perimeter Zone
0
NO
YES
17
WATCHDOG RESET
305
E
System reset Zone
0
NO
NO
18
LOOP TROUBLE RES
332
R
Polling loop short Zone
0
NO
NO
19
SIREN FUSE RESTORE
321
R
Bell 1
0
NO
NO
20
FAIL TO REPORT
350
E
Communication
trouble
0
NO
NO