Configuration (CONFIG)
REINSTATE BYPASS - If set, the panel will automatically unbypass any zones, which have been
bypassed by the user, when the panel is disarmed. The default is SET (reinstate bypassed zones).
KEY TONES
If set, a tone will be generated when a key is pressed on the keypad. The default is SET.
TAMPER TONES
If set, the speaker will sound an alarm when a zone has been tampered. The default is SET.
ADVISORY TONES
If set, the speaker will sound advisory tones to the user when the panel cannot perform an action
e.g. incorrect option selected, or panel cannot arm after the arm key has been pressed.
BOX TAMPER
If set, the speaker will sound an alarm when the panel is removed from its wall mounting bracket.
The default is SET.
SYSTEM VOLTAGE
The panel will monitor the state of its power supply and will generate a fault condition if the
supply voltage is not within acceptable limits. The default is SET (monitored).
AC MAINS
If set, the panel will generate a fault condition if the AC supply is not present. The default is SET
(monitored).
ALARM VOLUME
The volume of the internal speaker when the panel is in alarm. Values range between 0 (off) and 10
(loudest). The default value is 10.
ALARM TONES
If set, the internal speaker will sound when the panel is in an alarm condition. The default is SET (on).
TROUBLE TONES
If set, the internal speaker will sound when there is a trouble condition on the panel (e.g. AC failure
or low battery). The default is SET.
CHIME TONES
If set, the internal speaker will issue chime tones when a chime zone is violated (see Chime under
the Setting Up the Zones section). The default is SET.
ENTRY TONES
If set, the internal speaker will sound when the entry delay is active (the user is entering the pre-
mises). The default is SET.
EXIT TONES
If set, the internal speaker will sound when the exit delay is active (the user is exiting the premises).
The default is SET.
Rhino 232 Installation Manual 19
|