Programming Wireless Zones
If a zone has been selected as wireless, two steps are required to program a wireless device into a
zone.
STEP 1:
Select the wireless type (W TYPE)
Options are:
PIR Wireless Passive Infra-Red
DOOR CONTACT Wireless Door Contact
STEP 2:
Enter the Wireless Device Serial Number (W SERIAL). This menu is used to attach a wireless device
to a zone.
Select the Wireless Serial Number Menu
The serial number can be entered automatically by activating the tamper button on the wireless
device. Refer to the in-box leaflet for the wireless sensor.
Alternatively, the serial number for the wireless device can be entered on the keypad. The serial
number for the wireless device is printed on the sticker on the wireless device.
To type in the wireless serial number, type in the code that appears after the 0x written next to ‘ID’
on the label e.g. 00027A59.
See Appendix A - Hex Entry Mode.
Double Knock Zones
Double Knock zones only cause an alarm when:
The zone remains active for the duration of the ‘Double Knock Delay’
The zone is violated twice within the ‘Double Knock Delay’
SINGLE EOL
The detector has a normally closed contact. The EOL resistor is used to detect that there is a fault condition on the wire
to the sensor.
WIRELESS
The detector is wireless.
14 Rhino 232 Installation Manual
|