![FSI XM Series User Manual Download Page 9](http://html.mh-extra.com/html/fsi/xm-series/xm-series_user-manual_2340929009.webp)
© 2021 Flanders Scientific, Inc.
9
Menu - Function Menu
Contrast Optimize
Sets Optimize Modulation Mode to CONTRAST. When turned off the Backlight Modulation mode will
default to setting selected on Video menu.
Note, Optimization settings only apply if operating in Dynamic Luminance Mode. See Video
Menu section of this manual for details on modulation modes.
Area Marker
Use the Area Marker function to select what type of marker is displayed when the marker function is
active. The marker selections available from this option include most commonly used markers and
more complex user designed custom markers.
Safety Marker
Use the Safety Marker function to toggle the size, in percentage, of the safety marker displayed. This
option can be used by itself or in conjunction with the Area Marker function.
Center Marker
Toggles whether the center marker (cross-hair) is displayed when the marker is activated.
Load Profile
Saved profile configurations can now be loaded via function button. This acts as a “load” button only
as opposed to a toggle, so pressing a corresponding Function button twice does not revert to previous
pre-load state.
Please note: to avoid circular logic problems, loading profile configurations does NOT change
function button assignments. The function buttons are independent of the profile configurations.