© 2021 Flanders Scientific, Inc.
14
Menu - Color Menu
Color Menu
Function
ColorSystem
User
Scope
LUT Mode
Normal
Video
Range
SMPTE Full 4-1019
Color
Gamut
BT.709
System
Temperature
Default
OSD
EOTF
Gamma 2.4
Luminance Mode
100
Luminance Custom
45
ColorSystem
Select from GaiaColor, USER, LightSpace, CalMAN, and NONE.
On the XM310K
GaiaColor
is the factory default Color System. When in GaiaColor use Luminance
Mode, Gamut, Temperature, and EOTF selections to activate various calibration configurations.
GaiaColor is calibrated using the closed loop Factory Cal process. See calibration guides for details.
None
disables all calibration and calibration support and should not normally be used.
The
USER, LightSpace, and CalMAN
Color System selections are additional memory banks that
can support user generated 1D+3D LUT calibrations. These can be used with both static and dyanmic
luminance (backlight) selections. When used with the dynamic backlight selection the EOTF settings
will determine the baseline peak luminance and EOTF that the user generated 1D/3D LUTs sit ahead
of.
LUT Mode
Does not apply to GaiaColor Color System. Note: Dynamic (modulated) Luminance mode ONLY works
in Normal LUT mode. In USER, LightSpace, or CalMAN modes select Normal or Advanced.
In Normal Mode up to 6 LUT positions are accessible as follows:
Front DIT 1D LUT -> DIT 3D LUT -> Post DIT 1D LUT-> Front Calibration 1D LUT -> Calibration 3D LUT
-> Post Calibration 1D LUT (
Post Calibration 1D LUT not active / accessible in Dynamic LUM Mode
)
In Normal Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and all
3D LUTs are 17x17x17.cube format using only the header LUT_3D_SIZE 17.
The DIT LUT positions should be used for technical transforms or look LUTs, calibration LUTs should
normally only be stored in the Calibration LUT positions.
In Advanced Mode 3 LUT positions are accessible as follows:
Front Calibration 1D LUT -> Calibration 3D LUT -> Post Calibration 1D LUT
In Advanced Mode all 1D LUTs are 4096 entry point using 12bit values in the Flanders.lut format and
the 3D LUT is 33x33x33.cube format using only the header LUT_3D_SIZE 33.
LUTs can be saved to the display using the IP Remote Utility or directly from LightSpace or CalMAN.
Application Note: LUTs are applied within the range active on the monitor’s color menu.