FEM3500/FEM3500D/FEM3500M/FEM3500DM

Electromagnetic Lock

Electro-Magnetic Lock Description:

Power setting and Input 

Wiring connections:

The FEM3500 is an unmonitored single magnetic lock and FEM3500D is an unmonitored double magnetic 

lock with dual 12 or 24 volt settings. There are no Lock or Door status sensors on these units. For wiring 

instruction refer to figure 2.
The  FEM3500M  is  a  monitored  single  magnetic  lock  and  the  FEM3500DM  is  a  monitored  double 

magnetic lock with 12 or 24 volt settings. Each magnetic lock has a built-in Hall crystal for remote 

monitoring of Lock status (open or closed) through relay contacts rated at 24 VDC, 1.0 A max on 

visible  high  luminosity  backlight  indicator  position  on  the  aluminum  housing  and  a  Door  Status 

Sensors  (DSS)  for  remote  monitoring  of  Door  status  through  reed  switch  contact.  For  wiring 

instruction refer to Figure 1.

The (+) lead of the power source is connected to Pins 1 (VDC +) of the terminal block and the (-) lead 

is connected to Pin 2 (-). The operating switch or controlling contacts must be installed between the 

power source and the magnetic lock to reduce operating time of the magnetic lock to a minimum. The 

electromagnetic lock requires a filtered and regulated DC Power Source for optimal performance.
Remove the wiring cavity cover plate and check the position of the two shunts located on the PCB. A 

single shunt across pins 2 and 3 will set the operating voltage to 24 volts. A shunt between pins 1 to 

2 and a shunt between pins 3 to 4 sets the operating voltage to 12 volts.

These voltage shunts must be set correctly before 12 VDC or 24 VDC power is supplied to the 

Electromagnetic Lock to prevent damage to the unit.

 

1 2 3 4

1 2 3 4

-

_

LED LIGHT PANEL

R

B

G

R B G

HIC

VDC

C

NC

NO

C
NC
NO

+ 12/ 24 VDC

 12/ 24 VDC

LED

GREEN

BLACK

RED

R

B

G

GREEN

BLACK

RED

DSS WIRING:  BLUE, BLUE 

(

NORMALLY OPEN

)

DSS contact rating: 30 VDC

0.2 Amp max.

12 VDC

24 VDC

FEM3500/ FEM3500D PCB

1

2
3
4

GROUND

VOLTAGE

+

-

R
G

B
W

Figure 2

12 VDC

24 VDC

1 2 3 4

1 2 3 4

FEM3500M/ FEM3500DM PCB

Figure 1

Power Input

FEM3500/ FEM3500M

FEM3500D/ FEM3500DM

0.50 A
0.25 A

 2 x 0.50 A
2 × 0.25 A

12 VDC
24 VDC

Backlight Indicator OFF

Relay De-energized,

No Power on Magnetic Lock

Relay De-energized,
Relay Energized,

Power on Magnetic Lock and Door is Open.
Power on Magnetic Lock and Door Locked.

Backlight Indicator RED
 Backlight Indicator GREEN