3. Mount the sink top faucet in the hole and using an adjustable wrench (or hand) to hold the faucet, tighten
the 9/16" nut.
4. Connect the tube from the outlet side of the pH neutralizing cartridge to the faucet.
Start Up Procedure:
1. With everything connected, turn on the water check for leaks.
2. Let the water run for at least 5-10 minutes. This flushes the system on first time use.
3. Close the sink tap faucet. Check the system for leaks.
The system is now ready for use.
Caution for Your Safety
� Change filters regularly every 6 to 12 months.
� Use only cartridges suitable for this appliance.
� Flush system for 5 minutes after a period of non-use exceeding 30 days.
FILTER CHANGING PROCEDURES
All filters should be changed every 12 months at the latest or 8,000 litres. Not changing your filters regularly
can cause bacteria to grow and contaminate the water.
Sediment and Carbon Filters
1. Turn inline ball valve off.
2. Open faucet to help de-pressurize system.
Note: Lay a towel down to catch any small water spillage.
3. Unscrew filter housings by turning counter clockwise.
4. Remove old filters and discard. Then follow sanitizing procedure.
5. Insert new filters into appropriate housings.
6. Replace "O" rings as necessary. Be sure "O" ring is clean, lubricated and seated properly when tightening.
Never use Vaseline or any other petroleum based sealant. It may breakdown the "O" ring or the seat of the
filter housing and cause a failure (leak).
7. Flush the system for 5 – 10 minutes to get rid of any carbon fines. Then follow normal system start up
procedures.
RECOMMENDED SANITISING PROCEDURE
The best time to sanitize is when changing the filters. It is recommended to sanitize the whole system a
minimum of once a year.