2.4 Wiring the Fault Alarm Contact
The fault alarm contacts are in the middle of the terminal block connector as the
picture shows below. Inserting the wires, the IMC-1F1T will detect the fault status
of the power failure, and then forms an open circuit. The following illustration
shows an application example for wiring the fault alarm contacts.
1. The wire gauge for the terminal block should be in the range between 12
and 24 AWG.
2. The DC power input range is 12V ~ 48V DC and supports 24V AC.
3. Please just use one power input when using 24V AC.
Note
1. The wire gauge for the terminal block should be in the range of
12 ~ 24 AWG.
2. Alarm relay circuit accepts up to 24V, max. 1A currents.
Note
Fault
Fault Alarm Contacts
The Fault Alarm Contacts are
energized (CLOSE) for normal
operation and will OPEN when
failure occurs