YFG255 SERIES GAS RETHERMALIZERS
CHAPTER 1: SERVICE PROCEDURES
1-6
1.5.2 Replacing the Temperature Probe (cont.)
7.
Loosen and unscrew completely the compression nut, then the
pass-through nut from the cookpot. Proceed to the next step
before removing probe from cookpot.
Note:
The temperature probe can be removed through the top
of the cookpot as follows: Ensure the probe wires have been
removed from the connector (step 6). Remove the harness
insulation. The probe can be pulled through the cookpot from
the top (complete step 7 in this section, prior to removing
probe).
8.
Carefully remove the probe from the cookpot.
9.
Reverse steps for installation of new probe.
IMPORTANT:
When installing new probe, ensure probe is
positioned properly with the mounting hardware installed prior to
tightening the compression nut
. Once tightened, the probe cannot
be repositioned.
Remove the temperature probe.
Loosen and unscrew completely
the compression nut (bottom arrow)
first. Loosen the pass-through nut
(top arrow).