Frymaster SINBAD II Installation And Operation Manual Download Page 13

 

3-2 

 

PROBLEM 

Probable Causes 

Corrective Action 

A. 

ON/OFF rocker switch is in OFF 
position. 

A. 

Place rocker switch in the ON 
position. 

B. 

Unit is not plugged in. 

B. 

Plug unit in. 

C. 

Main circuit breaker is tripped. 

C. 

Reset circuit breaker. 

UNIT WILL NOT 

POWER UP or 

NOTHING HAPPENS 

WHEN “RUN” MODE 

IS SELECTED.  If the problem is not corrected by one of the above actions, call FASC. 

A. 

Dispensing chute is not properly 
positioned on the load cell arms. 

A. 

Reposition dispensing chute so that 
is firmly seated on the load cell 
arms.  Turn the unit OFF then back 
ON using the ON/OFF rocker 
switch.  Press the RUN switch 

RUN SWITCH 

INDICATOR AND 

PROGRAM SWITCH 

INDICATOR ARE 

FLASHING.  Simultaneous flashing of the run switch indicator and program switch indicator 

signals that the unit is not properly zeroed.  If the problem is not corrected by the 
above action, call FASC. 

A. 

Dispensing chute is full. 

A. 

If the dispense chute has been 
loaded but not dispensed, nothing 
will happen until the batch has been 
dispensed, except when the batch 
weight is increased. Insert a basket 
into the dispensing well to dispense 
batch. 

B. 

Unit is not in RUN mode. 

B. 

Press RUN switch once. 

NOTHING HAPPENS 

WHEN A BATCH 

SIZE SELECTOR IS 

PRESSED. 

If one of the above actions did not correct the problem, call FASC. 

A. 

The load cell may not have been 
satisfied within 30 seconds, normally 
because the hopper is empty or the 
fries have “bridged”. 

A. 

Check the hopper to verify that the 
deflector is properly positioned.  If 
there are fries in the hopper, verify 
that there is no bridging.  If the 
hopper is empty, reload the hopper.  
Press the PROGRAM switch once 
to place the unit back into opera-
tion. 

DISPENSE DOOR 

DOES NOT OPEN 

WHEN BASKET IS 

INSERTED. 

If the above action did not correct the problem, call FASC. 

A. 

If the erratic batch weights are 
occurring only occasionally, the 
probable cause is bumping, jarring, 
and/or unusual vibration (such as 
caused by inserting a basket with 
undue force, the slamming of a freezer 
door, or the passing of a nearby train).

A. 

Exercise care when working around 
the unit to avoid bumping or jarring 
it while it is in operation.  Ensuring 
that the unit is not touching 
adjacent walls, and placing the unit 
on a rubber mat will reduce the 
effect of environmental vibrations. 

ERRATIC BATCH 

WEIGHTS ARE 

BEING DISPENSED. 

B. 

If the erratic batch weights are 
occurring consistently, the probable 
causes are misaligned components 
(B1) or improperly programmed batch 
weights (B2). 

B1. 

Verify that the dispensing chute is 
properly positioned on the load cell 
arms, that the deflector is properly 
positioned in the hopper, and that 
the hopper is fully seated behind 
the locking rim on the cradle 
assembly. 

Summary of Contents for SINBAD II

Page 1: ...r a member of the Commercial Food Equipment Service Association recommends using CFESA Certified Technicians 819 5874 24 Hour Service Hotline 1 800 551 8633 MARCH 2005 SinBaD Installation and Operatio...

Page 2: ...OOD AND DRUG ADMINISTRATION COMPUTERS FCC This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2...

Page 3: ...nstallation Operating and Service Personnel 1 2 1 5 Definitions 1 2 1 6 Shipping Damage Claim Procedure 1 3 CHAPTER 2 Installation and Operation 2 1 Installation 2 2 2 2 Self Zeroing 2 2 2 3 Operation...

Page 4: ...SC or Distributor Service may also be ob tained by calling the Frymaster Service Department at 1 800 551 8633 When requesting service please have the following information ready Model Number Serial Nu...

Page 5: ...ervice Personnel Operating information for Frymaster equipment has been prepared for use by qualified and or authorized personnel only as defined in Section 1 5 All installation and service on Frymast...

Page 6: ...ives damaged 1 File a claim for damages immediately regardless of the extent of damages 2 Inspect for and record all visible loss or damage and ensure that this information is noted on the freight bil...

Page 7: ...NIT Load Cell Arms behind front face of Dispense Chute Lid Sight Glass Crumb Pan and Basket Locator Rack Shown Removed from Unit ON OFF Switch Hopper Optional Basket Rack Accessory Kit Proximity Switc...

Page 8: ...let of appropriate voltage refer to the data plate affixed to the upper right corner of the right side of the unit locking the casters and connecting the unit to an appropriate electrical source When...

Page 9: ...at the sight glass is installed If it is not installed fries will fall out of the hopper during operation 8 Place the ON OFF Rocker Switch in the ON position The switch will illuminate indicating that...

Page 10: ...til the new weight is attained If the batch weight is reduced the change will take effect with the next cycle after the dispensing chute is emptied If the dispensing chute does not fill within 30 seco...

Page 11: ...with that switch The switch s indicator will light momentarily then go out showing that the weight for that switch has been successfully recorded 6 Repeat steps 4 and 5 for each of the remaining numbe...

Page 12: ...s will disengage the hopper from its retainer allowing it to slide forward for removal Remove the dispensing chute by lifting it up from the load cell arms and carefully sliding it out toward you Thes...

Page 13: ...id not correct the problem call FASC A The load cell may not have been satisfied within 30 seconds normally because the hopper is empty or the fries have bridged A Check the hopper to verify that the...

Page 14: ...the drum will not turn or may turn erratically Verify that the dispense chute is properly positioned on the load cell arms C Batch weight of 2 25 lbs 1kg or greater has been programmed C The maximum w...

Page 15: ...cutive times within 5 seconds after the PROGRAM Switch is pressed If more time is taken or if a selector other than 1 is pressed the unit automatically returns to the STANDBY mode UNIT GOES BACK TO ST...

Page 16: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Page 17: ...eport Louisiana 71135 1000 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 Tech Support 1 318 219 7135 Price 4 00 PRINTED IN THE UNITED STATES...

Reviews: