1-22
1.12.2 3000 Controller Useful Codes
To enter any of the following codes: Press and hold the
button until
Main Menu
changing to
Product setup
is displayed. Press
to scroll to
Tech Mode
and press
.
TECH
MODE ENTER CODE
is displayed. Enter a code number below:
Change Fryer Type, CE/Non-CE, Fresh Oil Setup, Waste Oil Setup and Energy
Type – Enter
7628
.
Clear E-Log, Clear Passwords, Change Lane Count, Adjust Max Cook Temp and
Perform High Limit Test, – Enter
3000
.
Reset Factory Menu
- Enter
3322.
The controller display flashes and quickly counts
from 1-40 and switches to
off
. (
NOTE
: This will delete any hand-entered menu items).
Reset
BADCRC
Message
- Disconnect board locator plug (J3). Reinsert plug. Enter
9988.
Controller display switches to
off
. Remove and then restore power to the
controller using the 20-pin plug.
Change from F° to C°
- Enter
1658.
The controller displays
off
. Turn the controller
on and check temperature to see the temperature scale. If the desired scale is not displayed,
repeat.
Reset
RECOVERY FAULT CALL SERVICE
– Enter
0042
.
PASSWORDS
Product Setup Mode
: Press and hold the
button until
Main Menu
changing to
Product
setup
is displayed. Press the
button.
ENTER CODE
is displayed. Enter
1650
.
Vat Setup Mode
: Press and hold the
button.
Main Menu
changing to
Product setup
is displayed. Press
to scroll to
Vat Setup
and press
.
ENTER CODE
is displayed. Enter
1656
.
Tech Mode
: Press and hold the
button until
Main Menu
changing to
Product setup
is displayed. Press
to scroll to
Tech Mode
and press
.
TECH MODE
is displayed. Press
the
button.
ENTER CODE
is displayed. Enter
3000
or a code from above.
1.12.3 Service Required Errors
A SERVICE REQUIRED error alternating with YES displays on the controller. After YES is pressed the
alarm is silenced. The controller displays an error message from the list below three times with the
location of the error. Then the controller displays SYSTEM ERROR FIXED? YES/NO. Press YES if error
is fixed. If NO is chosen the system returns to cook mode for 15 minutes then redisplays error until
issue is fixed.