Frymaster FilterQuick easyTouch FQE30U Installation, Operation And Maintenance Manual Download Page 18

3–2 

3.1 Equipment Setup and Shutdown Procedures 

 

 WARNING 

The on-site supervisor is responsible for ensuring that operators are made aware of the 
inherent hazards of operating a hot oil filtering system, particularly the aspects of oil 
filtration, draining and cleaning procedures. 

 

 

CAUTION 

Before turning on the fryer, ensure there is power to the fryer and the controllers are 
OFF.  Ensure the frypot drain valves are closed.  Remove the basket support rack(s), if 
installed, and fill the frypot to the bottom OIL-LEVEL line.  If solid shortening is being 
used, make sure it is packed down into the bottom of the frypot. 

 

 

3.1.1 Setup  

 

 DANGER 

Never operate the appliance with an empty frypot.  The frypot must be filled to the 
bottom OIL-LEVEL line with water or oil before energizing the elements.  Failure to do so 
will result in irreparable damage to the elements and may cause a fire.   

 

 DANGER 

Remove all drops of water from the frypot before filling with oil.  Failure to do so will 
cause spattering of hot liquid when the oil is heated to cooking temperature. 

 

 

 WARNING 

The  FQE30-T is  not intended to use solid shortening without a solid shortening kit 
installed.  The use of solid shortening without a solid shortening kit will clog the top off 
oil lines. The oil capacity of the FQE30-T electric fryer is 32 lbs. (3.8 gallons/14.5 liters) at 
70°F (21°C) for a full-vat and 18 lbs. (2.2 gallons/8.33 liters) at 70°F (21°C) for each half of a 
d

ual-vat. 

 
1.

 

Fill the frypot with cooking oil to the bottom OIL LEVEL line located on the rear of the frypot.  
This will allow for oil expansion as heat is applied.  Do not fill cold oil any higher than the 
bottom line; overflow may occur as heat expands the oil.  For bulk oil systems see Section 2.1.8 
of the FQ

4000 Controller Operation Manual 8197474

 for instructions to fill the vat from bulk. If 

solid shortening is used, make sure it is packed down into the bottom of the frypot.

 

2.

 

Ensure that the power cord(s) is/are plugged  and locked (if applicable)  into the appropriate 
receptacle(s).  Verify that the face of the plug is flush with the outlet plate, with no portion of 
the prongs visible. 

3.

 

Ensure that the power is switched on with the master switch, located behind the fryer door 
cabinet on the front panel of the component box, next to the fuse. 

4.

 

Ensure that the controller is switched ON.  The fryer will automatically enter the melt cycle 
mode if the frypot temperature is below 180ºF (82ºC) and will display 

MELT CYCLE IN 

PROGRESS

. (

NOTE:

  During the melt cycle, the elements will energize for a few seconds, then go 

out for a longer period.)  The shortening must be stirred occasionally during the heating 
process to ensure all the shortening in the vat is  liquefied. When the frypot temperature 

Summary of Contents for FilterQuick easyTouch FQE30U

Page 1: ...isit our website for the latest manual Part Number FRY_IOM_8197522 11 2019 8197522 Original Instructions CAUTION READ THE INSTRUCTIONS BEFORE USING THE FRYER Keep these instructions for future referen...

Page 2: ...ion Manual of the U S Food and Drug Administration WARNING Improper installation adjustment maintenance or service and unauthorized alterations or modifications can cause property damage injury or dea...

Page 3: ...it It is designed for a tight fit and should only be removed for cleaning DANGER Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to...

Page 4: ...ordance with the procedures described in this manual Mobile marine or concession conditions of this fryer should be avoided to ensure optimum performance WARNING Do not block the area around the base...

Page 5: ...ve will lead to the outflow of the hot contents of the fryer that can cause injury WARNING The OQS Oil Quality Sensor may be damaged by the following 1 Incorrect assembly of the filter pan allowing Ma...

Page 6: ...n 3 Operation Instructions 3 1 Section 4 Preventative Maintenance 4 1 Section 5 Operator Troubleshooting 5 1 Section A Bulk Oil Instructions A 1 Section B JIB Preparation with Solid Shortening Option...

Page 7: ...d in batteries of up to five vats Each frypot is equipped with a temperature probe for precise temperature control FQE30 T fryers are shipped completely assembled All fryers are shipped with a package...

Page 8: ...been shown to meet the Class B limits These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment...

Page 9: ...e familiarized themselves with the equipment functions or who have had previous experience with the operation of the equipment covered in this manual QUALIFIED INSTALLATION PERSONNEL Qualified install...

Page 10: ...2 Inspect For and Record All Visible Loss or Damage and ensure that this information is noted on the freight bill or express receipt and is signed by the person making the delivery 3 Concealed Loss o...

Page 11: ...or distributor A list of Frymaster Factory Authorized Servicers FAS s is located on the Frymaster website at www frymaster com If you do not have access to this list contact the Frymaster Service Depa...

Page 12: ...e country in which the equipment is installed Service may be obtained by contacting your local Frymaster Authorized Servicer DANGER Building codes prohibit a fryer with its open tank of hot oil being...

Page 13: ...appliance when installing or servicing this equipment DANGER Do not attach an apron drainboard to a single fryer The fryer may become unstable tip over and cause injury The appliance area must be kept...

Page 14: ...inside of the fryer door for proper voltages The equipotential grounding lug indicated by illustration right allows all the equipment in the same location to be electrically connected to ensure there...

Page 15: ...t is level both side to side and front to back To level fryers adjust the casters being careful to ensure the fryer s are at the proper height in the frying station The front right caster may be locke...

Page 16: ...adle Open the fryer door typically the far right door or third door and remove the cross brace used for shipping support by removing the four screws see Figure 1 Install the JIB cradle shipped may dif...

Page 17: ...ing Elements Top Cap Bezel Control Panel FQ4000 Controller Shown Filter Pan Power Switch Pre Filter Screen JIB Oil Reservoir Basket Holder Pre Filter Wrench Reset Switch USB Port TYPICAL CONFIGURATION...

Page 18: ...ity of the FQE30 T electric fryer is 32 lbs 3 8 gallons 14 5 liters at 70 F 21 C for a full vat and 18 lbs 2 2 gallons 8 33 liters at 70 F 21 C for each half of a dual vat 1 Fill the frypot with cooki...

Page 19: ...rocedures and for operating instructions for the built in filtration system 3 3 Manual Top Off Automatic Top Off and JIB Refill The fryer can be configured for either manual top off or for both manual...

Page 20: ...el is low and displays TOP OFF OIL EMPTY see Figure 2 Press the check button to clear the screen Once the reservoir is refilled and or replaced press and hold the orange reset button next to the oil r...

Page 21: ...er system for use Operation of the system is covered in the FilterQuick Touch Controller Manual WARNING The on site supervisor is responsible for ensuring that operators are made aware of the inherent...

Page 22: ...screen in the center of the bottom of the pan then lay a sheet of filter paper on top of the screen overlapping on all sides see Figure 11 If using a filter pad ensure the rough side of the pad is up...

Page 23: ...proof container at the end of frying operations each day Some food particles can spontaneously combust if left soaking in certain shortening material WARNING Do not bang fry baskets or other utensils...

Page 24: ...cleaner and the length of time the cleaner remains on the food contact surfaces 4 2 DAILY CHECKS AND SERVICE 4 2 1 Inspect Fryer and Accessories for Damage Look for loose or frayed wires and cords lea...

Page 25: ...dry each part DO NOT use steel wool or abrasive pads to clean these parts The scratches that result from such scrubbing make subsequent cleanings more difficult 4 2 5 Clean around AIF and ATO sensors...

Page 26: ...screen 1 Wearing protective gloves use the supplied wrench to remove the cap from the pre filter Figure 2 2 Use a small brush to clear debris from the attached screen Figure 3 3 Clean under a water t...

Page 27: ...ng elements are in good condition with no carbon caramelized oil build up Inspect the elements for signs of extensive dry firing Verify that the tilt mechanism is working properly when lifting and low...

Page 28: ...n selection see section 2 3 7 of the FQ4000 Controller Operation Manual one at a time Verify proper functioning of each oil return valve by activating the filter pump using the fill vat from drain pan...

Page 29: ...tion involves taking steps to ensure that it doesn t happen again If a controller malfunctions because of a poor connection check all other connections too If a fuse continues to blow find out why Alw...

Page 30: ...s ignored on a prior prompt Change the filter pad and ensure the filter pan has been removed from the fryer for a minimum of 30 seconds Do NOT ignore CHANGE FILTER PAD prompts Fryer does not heat A Po...

Page 31: ...ature measuring circuitry including the probe or damaged controller wiring harness or connector Shut the fryer down and call your FAS for assistance Heating indicator is on but fryer is not heating Th...

Page 32: ...in or circuit breaker is tripped B Pump motor has overheated causing the thermal overload switch to trip C Blockage in filter pump A Verify that the power cord is fully plugged in and the circuit brea...

Page 33: ...pad paper Verify if using a pad that the rough side is facing up Verify that O rings are present and in good condition on filter pan connection fitting C Clean pre filter see section 4 5 4 and ensure...

Page 34: ...yer The error will be re displayed every 15 minutes until the issue is repaired Auto filtration and auto top off are disabled until the fryer is reset ENTER CODE 13 FAS tech enters tech code to reset...

Page 35: ...switch is off only on solid shortening units F Blown fuse A Fryer temperature must be at setpoint B Ensure that the oil in the top off reservoir is above 70 F 21 C C Ensure the top off reservoir is n...

Page 36: ...than 410 F 210 C or in CE countries 395 F 202 C E17 HIGH LIMIT 2 EXCEEDED High limit switch has opened E18 HIGH LIMIT PROBLEM DISCONNECT POWER Vat temperature exceeds 460 F 238 C and the high limit ha...

Page 37: ...CALL SERVICE The controller has an unknown error E53 CAN BUS ERROR CALL SERVICE Communications are lost between boards E54 USB ERROR USB connection lost during an update E55 SYSTEM INTERFACE BOARD 2...

Page 38: ...6 If issue continues contact a FAS E73 TPM RANGE HIGH The TPM reading is too high for a valid OQS reading Dispose the oil E74 OQS ERROR The OQS has an internal error If issue continues contact a FAS E...

Page 39: ...to be idle to set these settings 1 With the controller soft powered off press the HOME button 2 Press the Settings button 3 Press the Service button 4 Enter 3000 5 Press the checkmark button 6 Press...

Page 40: ...he momentary switch located above the top off reservoir allows the operator to fill the jug from the bulk oil storage tank see Figure 3 To fill the jug press and hold the top off reset button until th...

Page 41: ...er will ONLY operate with bulk oil systems that have a three pole float switch If the float switch is the older two pole switch call the bulk oil provider These float switches are polarity specific wh...

Page 42: ...sides using the existing holes See Figure 5 8 On the back side of the melter attach the white two pin connectors and plug in the black connector to the outlet box shown in Figure 6 9 Ensure the melti...

Page 43: ...and reset the top off system DO NOT ADD hot oil to the shortening melter The temperature of the oil reservoir should not exceed 140 F 60 C Add small amounts of solid shortening to the reservoir to en...

Page 44: ..._IOM_8197522 11 2019 8197423 WWW WELBILT COM Welbilt provides the world s top chefs and premier chain operators or growing independents with industry leading equipment and solutions Our cutting edge d...

Reviews: