background image

   
 

 
 

PRIVATE AND CONFIDENTIAL © 2016 FRTEK CO., LTD. 

 

7

 

FR-RLRL45US

 Operating Manual

 

 

 

 

 

Chapter 1  

Safety & Certification Notice

 

 

 

 

 

 

 

 

 

 

 

 
1.1   

Health and Safety Warnings 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for FR-RLRL45US

Page 1: ...CO LTD 1 FR RLRL45US Operating Manual FR RLRL45US Operating Manual Document Reference Company Fiber Radio Technologies Version Ver 2 2 Document Status Release 1 Issue Data 2017 01 Department R D Division Team 4 Author Manager Jun Hyun Lee ...

Page 2: ...oduction and reuse of all or part of the information in this service manual to the 3rd party are strictly prohibited Trademark FRTek is trademarks or registered trademarks of FRTek and or its affiliates in the U S and other countries Please read this service manual before installation and operation and use the system in proper and safe use in accordance with contents of this manual If you have any...

Page 3: ...History Version Issue Date Details of Revision Author Authorizing Manager V 1 0 16 08 19 Original Jun Hyun Lee V 2 0 16 10 03 Revision Jun Hyun Lee V 2 1 16 10 19 Revision Jun Hyun Lee V 2 2 17 01 03 Revision Jun Hyun Lee This manual is produced by R D Division Team 4 Printed in FRTek ...

Page 4: ...nstallation Location 11 2 1 2 ICS Repeater General Information 11 Chapter 3 System Configuration 13 3 1 System Figuration 14 3 2 System Module Configuration 15 3 3 System Port Configuration 15 3 4 AC Power Cable 16 3 5 Antenna 17 Chapter 4 System Specification 18 4 1 RF Specification 19 4 2 Power Specification 20 4 3 Environment Specification 21 Chapter 5 FR RLRL45US Installation 22 5 1 Installati...

Page 5: ...1 ICS Repeater Service Application Network 11 Figure 2 Repeater Figuration 14 Figure 3 ICS Repeater External Port Configuration 15 Figure 4 AC Power Cable 16 Figure 5 RET Port Connector SU 20SPR 8S Pin Map 17 Figure 6 Connection of grounding cable 23 Figure 7 ICS Antenna Cable Connection 23 ...

Page 6: ...l EVM Error Vector Magnitude GUI Graphical User Interface HPA High Power Amp HAAT Height Above Average Terrain ICS Interference Cancellation System PSU Power Supply Unit SISO Single Input Single Output VSWR Voltage Standing Wave Ratio USB Universal Serial Bus 3GPP 3rd Generation Partnership Project EMS Enetrprise Management Systems RET Remote Electric Tilt ...

Page 7: ...PRIVATE AND CONFIDENTIAL 2016 FRTEK CO LTD 7 FR RLRL45US Operating Manual Chapter 1 Safety Certification Notice 1 1 Health and Safety Warnings ...

Page 8: ...area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense 1 1 2 FCC Part 15 21 statement Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Obey all general and regional installation and safety regulations relating to work on h...

Page 9: ... a CONSUMER device It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS You MUST have an FCC LICENSE or express consent of an FCC License to operate this device Unauthorized use may result in significant forfeiture penalties including penalties in excess of 100 000 for each continuing violation ...

Page 10: ...PRIVATE AND CONFIDENTIAL 2016 FRTEK CO LTD 10 FR RLRL45US Operating Manual Chapter 2 System Overview 2 1 System Overview ...

Page 11: ... regions with black spot where BTS installation is not available ICS repeater supports CDMA forward reverse direction service with 5MHz 10MHz and 15MHz bandwidth and 5MHz bandwidth for LTE service at the same time supporting forward direction gain control and ALC Automatic Level Control function for controlling tilt each donor server antenna Figure 1 ICS Repeater Service Application Network 2 1 1 ...

Page 12: ... 24 x 19 x 15 Weight Below 35kg Excluding mounting bracket Maximum DL output power is 30Watt Total In case of 3 blocks 10Watt 40dBm per block In case of 2 blocks 15Watt 41 76dBm per block In case of 1 block 20Watt 43 01dBm per block Maximum UL output power is 2Watt Total In case of 3 blocks 0 67Watt 28 26dBm per block In case of 2 blocks 1Watt 30dBm per block In case of 1 block 1 33Watt 31 23dBm p...

Page 13: ... AND CONFIDENTIAL 2016 FRTEK CO LTD 13 FR RLRL45US Operating Manual Chapter 3 System Configuration 3 1 Configuration 3 2 System Module Configuration 3 3 System Port Configuration 3 4 AC Power Cable 3 5 Antenna ...

Page 14: ...change This equipment is designed to carry assemble install easily Enclosure of this equipment is designed to protect breaking into dust pollutants and insect Enclosure of the equipment is designed to avoid the occurrence of vibration or malfunction due to external environmental conditions earthquake Zone4 mechanical damage All parts this equipment is made smoothly The system is composed of suffic...

Page 15: ... performs ICS signal processing after receiving main signal and feedback signal to and also embedded MCU and performs MCU function PSU 1 It supplies power to each module after converting from AC to DC EMS Board 1 It has a function to control and monitor of repeater and to provide software upgrade RET Interface Board 1 Surge protection circuit of AISG 2 0 Port RET 3 3 System Port Configuration Figu...

Page 16: ...ector Spec SMA Type Female At the bottom of enclosure UL MON It controls systems and monitor system status Connector Spec SMA Type Female At the bottom of enclosure RET AISG 2 0 Control tilting function by cascading donor server antenna remotely Connector Spec SU 20SPR 8S At the bottom of enclosure Local GUI Control and check status of repeater with connection between PC and communication cable by...

Page 17: ... Connector SU 20SPR 8S Pin Map Part 27 50 Antennas must be installed in accordance with FCC 27 50 Over 17dBi gain antennas the height of the antenna above average terrain HAAT must not exceed xxxm For different gain antennas refer to the relevant rules Part 90 635 requirement Antennas must be installed in accordance with FCC 90 635 Over 17dBi gain antennas the height of the antenna above average t...

Page 18: ...PRIVATE AND CONFIDENTIAL 2016 FRTEK CO LTD 18 FR RLRL45US Operating Manual Chapter 4 System Specification 4 1 RF Specification 4 2 Power Specification 4 3 Environment Specification ...

Page 19: ...pied Bandwidth 25 MHz configurable 3 channels contiguous and or non contiguous in 5MHz increments Band Flatness 3dB p p In case of 6 cascading Frequency Stability 0 05ppm Waveform Quality CDMA Rho 0 99 LTE 5M 10M EVM 3 2 E TM3 1 64QAM EVM 5 1 E TM3 2 16QAM EVM 7 1 E TM3 3 QPSK CDMA Rho 0 96 In case of 6 cascading LTE 5M 10M EVM 15 E TM3 1 64QAM In case of 6 cascading EVM 15 E TM3 2 16QAM In case o...

Page 20: ...unction DL Over 45 7dBm Total Can configure shut down level UL 34dBm Total System Noise Figure Within 4dB System Delay Period CDMA 4 0usec DL UL LTE 5M 10M 4 0usec DL UL Standing wave ratio VSWR 1 5 1 DL UL ALC Range 30dB DL UL Feedback signal remove function G I 15dB Maximum DL output power is 30Watt Total In case of 3 blocks 10Watt 40dBm per block In case of 2 blocks 15Watt 41 76dBm per block In...

Page 21: ...tration 4 3 6 Without external fan it maintains proper temperature in enclosure 4 3 7 Complied with Telcordia GR63 CORE Dust 4 3 8 This system is designed with compatible component for FCC UL Certificate 4 3 9 Major environment test condition is same as following table Items Condition of application Requirements Storage Environment Condition Temperature 40 85 Humidity 5 95 No change of system func...

Page 22: ...PRIVATE AND CONFIDENTIAL 2016 FRTEK CO LTD 22 FR RLRL45US Operating Manual Chapter 5 FR RLRL45US Installation 5 1 Installation ...

Page 23: ...45US Installation 5 1 Installation 5 1 1 Grounding Connection Figure 6 Connection of grounding cable This system connects with enclosure grounding and building ground to avoid electrical hazard and protect system operator 5 1 2 Antenna Connection Figure 7 ICS Antenna Cable Connection ...

Page 24: ...n be selective depending on the installation environment This system is composed of 2 antenna port Donor and server antenna it is DIN Type Connector Warning Antenna should be installed according the regulation FCC 27 50 for different gain antennas refer to the relevant rules 5 1 3 AC Power Connection ICS repeater uses AC110V 240V as a main power Power cable includes a plug following information is...

Page 25: ...g Manual Fiber Radio Technologies CO LTD All rights reserved Copyright ⓒ FRTek Co Ltd All rights reserved Without any authorization of FRTek Co Ltd the disclosure distribution reproduction and reuse of all or part of the information in this service manual to the 3rd party are strictly prohibited ...

Reviews: