Specifications:

Recommended input voltage range: DC 4~8.4V (1~2s Lipo or 4~6s NiMH)

Number of servos: up to 15

Operating temperature: -20

~75

Weight: 37g

Dimension: 77×43×22mm

Features:

High voltage servo supported

Overload protection on each channel

Compatible with other FrSky S.Port products

Dual power and dual receiver

Integrated S.Port telemetry feedbacks (voltage, current, capacity, overload indication, etc.)

Settable servo signal output period: 50Hz of servo outputs (20ms period) or equal to the input of SBUS cycle

                                              FrSky Electronic Co., Ltd                    www.frsky-rc.com                    Contact us : [email protected]  

Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China    Technical Support: [email protected] 

                                              FrSky Electronic Co., Ltd                    www.frsky-rc.com                    Contact us : [email protected]  

Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China    Technical Support: [email protected] 

Introduction:

Thank you for purchasing FrSky RB-20. It is a high-performance and multi-function unit. In order to fully enjoy the 

benefits of this system, please read the instruction manual carefully and set up the device as described below.

Instruction Manual for FrSky  RB-20

Working State

Red LED    Green LED          State
    Off 

         On            Normal

    On 

         Off           Abnormal

Overload Protection:

The RB-20 has overload protection function through a circuit inside on each servo output. If current overload

happens, the affected servo output will be disconnected from the power supply while the remaining servo outputs

are still power on.

The allowed continuous current output on CH1~CH15, S.PORT, RX 1IN, RX 2IN is 5A. When the continuous 

current is over 10A, the RB-20 will activate overload protection immediately 23

℃.

Temperature       I

hold

 (A)             I

trip

 (A)

       23

             5.00               10.00

       50

             3.95                7.90

       70

             3.35                6.70

Overview:

CH1~CH15

 - connect up to 15 servos (PWM)

RX1 S.P

 - connect to the S.Port of RX1

RX2 S.P

 - connect to the S.Port of RX2

S.PORT

 - connect to the S.Port of FrSky products with S.Port

RX1 IN

 - connect to the SBUS port of the receiver

RX2 IN

 - connect to the SBUS port of the receiver

BATT 1&BATT 2

 - MPX connectors for batteries or BEC connection, supply power for RB-20 and connected 

receivers

LED R 
LED G

RX2 S.P
RX1 S.P

DC

Caution: Do not connect power supplies to CH1~CH15, S.PORT, RX1 S.P, RX2 S.P, RX1 IN and RX2 IN.

Power Supply:

Power supply of RB-20 could be provided from either one battery/BEC (connect via BATT1 or BATT2), or two 

(connect to BATT1 and BATT2). When two power supplies are used, make sure both supply the maximum 

continuous current of 40A and the maximum peak current of 120A. Otherwise overload protection could not 

function efficiently.

If the voltages of two power supplies are the same, power can be used from both supplies at the same time; 

If the voltages of two power supplies are different, the power comes from the one with the higher voltage, and 

each supply is isolated from each other instead of shared.

Application of batteries with different capacity, number of cells and chemistry type is allowed.

Please ensure output power on one of the two power supplies is no less than the maximum operation power of 

the connected devices (servos, etc.), or insufficient power supply on the connected devices may occur.

The RB-20 is a switchboard connected to power supplies, receivers, servos and S.Port sensors. The RB-20 does 

not contain circuitry to stabilize or regulate voltage to the servos. The level of the input voltage is equal to the level 

of (output) supplied voltage to the servos. Be sure to match the proper type of servos with your selected power 

supply (for example: when using 2 LiPo cells without a regulator, it is necessary to use servos labeled “High 

Voltage”).

Do not use Y harness to connect more than one servo to each servo output.

Connection:

1
2
3
4
5
6
7
8

SBUS

8 / 1 6 C H     T E L E M E T R Y

RSSI

POR

T

SBUS

1
2
3
4
5
6
7
8

SBUS

8 / 1 6 C H     T E L E M E T R Y

RSSI

POR

T

SBUS

LED R 
LED G

RX2 S.P
RX1 S.P

DC

FrSky S.Port Sensors

Note 

      R-XSR,G-RX8 and RX8R PRO could enable/disable telemetry through S.Port.

      X8R,X4R and XSR could enable/disable telemetry through S.Port with the firmware above and 

V180125. 

What's New!

Multi-channel output 

Higher operating current (The current is twice as big as RB) and supporting high-current servos

(Please refer to the chart in Overload Protection)

Automatically selected telemetry between RX1 and RX2:

decide on/off of telemetry on RX1 and RX2 through RX1 S.P and RX2 S.P

Reviews: